3 description of device, Description of device – SMA SB 3300TL Installation User Manual

Page 30

Advertising
background image

Technical Documentation

SMA

Technologie AG

Page 30

SB3300TL-11:SE2006

Installation Guide

7.3 Description of Device

You will find a detailed device description in the Operating Instructions.

General Data

External interfaces

Efficiency

The efficiency of the Sunny Boy 3300TL depends on the DC input voltage from the
PV modules. The higher the voltage the higher is the efficiency of the Sunny Boy
3300TL.

Protection degree (DIN EN 60529)

IP65

Dimensions (width x height x depth)

approx. 470 mm x 490 mm x 225 mm

Weight

approx. 28 kg

Data transmission via Powerline

optional

Data transmission via separate data cable

optional,
RS232 / RS485, electrically separated

Data transmission via radio

optional

Max. efficiency at nominal voltage

η

m ax

95.6 %

European weighted efficiency

η

euro

94.5 %

Sunny Boy 3300TL

0

500

1000

1500

2000

2500

3000

300 V

400 V

520 V

Output Power [kW]

Total

E

ffic

ien

cy [

%

]

Advertising