Modified Parameters

Table 2 Deleted Parameters from Standard Software

Table 3 Deleted Multi-function Digital Inputs (H1 Group)

Table 4 Deleted Multi-function Digital Outputs (H2 Group)

Table 5 Modified Parameter Setting Ranges

Parameter

Name

A1-06

Application Preset

b3-06

Output Current 1 during Speed Search (Estimation Type)

b3-10

Speed Search Detection Compensation Gain (Estimation Type)

b3-24

Speed Search Method Selection

b8-01 ~ b8-19

Energy Saving Control Parameters

C6-01

Normal/Heavy Duty Selection

E3-01

Motor 2 Control Method Selection

L2-06 ~ L2-11

KEB Parameters

L3-11

ov Suppression Function Selection

n3-01 ~ n3-23

High Slip Braking/Overexcitation Deceleration Parameters

T1-01 ~ T1-08

Motor Tuning Parameters

Setting

Function

65

KEB Ride-thru 1 (N.C.)

66

KEB Ride-thru 1 (N.O.)

68

HSB (High Slip Braking)

7A

KEB Ride-thru 2 (N.C.)

7B

KEB Ride-thru 2 (N.O.)

Setting

Function

4A

KEB Operation

Parameter

Name

Setting Range

A1-02

Control Method Selection

0

b4-01

Timer Function On-Delay Time

0.0 ~ 3000.0 s

b4-02

Timer Function Off-Delay Time

0.0 ~ 3000.0 s

b5-20

PID Setpoint Scaling

0, 1, 3

H6-01

Pulse Train Input Terminal RP Function Selection

0, 1, 2

L3-02

Stall Prevention Level during Acceleration

0 ~ 170%