4 modified parameters – Yaskawa 1000 Hz High Frequency User Manual

Page 12

Advertising
background image

4 Modified Parameters

12

YASKAWA ELECTRIC EZZ020793 1000 Hz High Frequency Custom Software Supplement

Table 9 Modified Monitors

Table 10 Deleted Monitors

Table 11 MEMOBUS/Modbus Communication Data

E1-04

Maximum Output Frequency

0.0 ~ 1000.0

60.0 Hz

E1-06

Base Frequency

0.0 ~ 1000.0

60.0 Hz

E1-07

Mid Output Frequency

0.0 ~ 1000.0

3.0 Hz

E1-09

Minimum Output Frequency

0.0 ~ 1000.0

1.5 Hz

E1-11

Mid Output Frequency 2

0.0 ~ 1000.0

0.0 Hz

E3-04

Motor 2 Maximum Output Frequency

0.0 ~ 1000.0

60.0 Hz

E3-06

Motor 2 Base Frequency

0.0 ~ 1000.0

60.0 Hz

E3-07

Motor 2 Mid Output Frequency

0.0 ~ 1000.0

3.0 Hz

E3-09

Motor 2 Minimum Output Frequency

0.0 ~ 1000.0

1.5 Hz

E3-11

Motor 2 Mid Output Frequency 2

0.0 ~ 1000.0

0.0 Hz

L4-01

Speed Agreement Detection Level

0.0 ~ 1000.0

0.0 Hz

L4-03

Speed Agreement Detection Level (+/-)

-999.9 ~ 999.9

0.0 Hz

Parameter

Name

Setting Range

U1-01

Frequency Reference

0.0 ~ 1000.0 Hz

U1-02

Output Frequency

0.0 ~ 1000.0 Hz

U1-16

Output Frequency after Soft Start

0.0 ~ 1000.0 Hz

U2-03

Frequency Reference at Previous Fault

0.0 ~ 1000.0 Hz

U2-04

Output Frequency at Previous Fault

0.0 ~ 1000.0 Hz

U4-14

Peak Hold Output Frequency

0.0 ~ 1000.0 Hz

Parameter

Name

U1-05

Motor Speed

U1-09

Torque Reference

Register

Name

Data

2H

Frequency Reference

Setting upper limit 40000 to FFFFH

3EH

Output Frequency RPM

Deleted

Parameter

Name

Setting Range

Default

Advertising