Revision history – Yaskawa 1000 Hz High Frequency User Manual

Page 17

Advertising
background image

6 Application Notes

YASKAWA ELECTRIC EZZ020793 1000 Hz High Frequency Custom Software Supplement

17

Precautions for High Frequency/Low Impedance Motors

High frequency motors exhibit different characteristics than standard 60/120 Hz maximum

frequency motors. The low impedance associated with these high frequency motors often

requires manually programming a custom V/f pattern into the E1 parameter group to obtain

proper performance and rated power from the drive-motor combination.
The low impedance may also cause excessive motor current. In addition to considering the

use of an output reactor, it may be advantageous to oversize the drive to accommodate the

high peak current that may result from the low impedance motor. Using a drive that is at

least one or two models larger than the motor FLA may also help eliminate the oL2 faults.
Compatibility between the drive, motor, and the reactor is best accomplished via testing and

observation of the motor current waveform with an oscilloscope.

Refer to Using an Output

Reactor on page 15

.

Revision History

The revision dates and the numbers of the revised manuals appear on the bottom of the back

cover.

Revision No.

Publication Date

Software No.

Revised Content

First Version

2007.11.09

VSV905030

-

<1>

2008.03.06

VSV905030

Cover addition

<2>

2008.05.06

VSV905030

English addition

<3>

2008.06.03

VSV905030

YEA revision, changed document number

MANUAL NO.

ޓTOBP C730600 28A

Published in Japan May 2008 07-12

Date of
publication

Date of original
publication

Revision number

1

Advertising