4 Option Components
12
YASKAWA ELECTRIC TOBP C730600 62B 1000-Series Option SI-ET3 Installation Manual
◆
Connector
Table 3 Communication Connector
MECHATROLINK-III Connector
Pin No.
Signal
Name
I/O
Function
1
TXD_P
I/O
Send data (+):
OUT
2
TXD_N
I/O
Send data (-):
OUT
3
RXD_P
I/O
Receive data (-):
IN
4
(NC)
–
–
5
(NC)
–
–
6
RXD_N
I/O
Receive data (-):
IN
7
(NC)
–
–
8
(NC)
–
–
Shell
SLD
–
Shield
2 4 6 8
1 3 5 7
CN2
CN1