7 troubleshooting – Yaskawa MECHATROLINK-III User Manual

Page 30

Advertising
background image

7 Troubleshooting

30

YASKAWA ELECTRIC TOBP C730600 62B 1000-Series Option SI-ET3 Installation Manual

LED Operator Display

Fault Name

to

oFA30 to oFA43

Option Card Connection Error (CN5-A)

Communication ID error.

Cause

Possible Solution

Option hardware fault

Replace the option.

LED Operator Display

Fault Name

oFb00

Option Fault (CN5-B)
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option connected to
the drive.

Connect the correct option to CN5-A.

LED Operator Display

Fault Name

oFb02

Option Fault (CN5-B)
Two identical options are connected at the same time.

Cause

Possible Solution

Options AI-A3 or DI-A3 are
connected to the CN5-B port with an
option connected to CN5-A.

• Only one type of AI-A3, DI-A3 or SI-†† option can be connected to the

drive

• The SI-ET3 option can only be connected to CN5-A

LED Operator Display

Fault Name

oFC00

Option Fault (CN5-C)
Non-compatible option is connected.

Cause

Possible Solution

Non-compatible option connected to
the drive.

Connect the correct option to CN5-A.

LED Operator Display

Fault Name

oFC02

Option Fault
Option Flash write mode.

Cause

Possible Solution

Options AI-A3 or DI-A3 are
connected to the CN5-B port while an
option connected to CN5-A.

• Only one type of AI-A3, DI-A3 or SI-†† option can be connected to the

drive

• The SI-ET3 option can only be connected to CN5-A