3 wiring – Yaskawa DC Power Input Σ-V Series User Manual

Page 16

Advertising
background image

E-14

3 Wiring

3.1 Input Power Supply, Molded-case Circuit

Breaker, and Fuse

Use input power supplies that meet the following conditions.

• The main circuit power supply must be a 24-VDC or a 48-VDC power

supply.

• The control circuit power supply must be a 24-VDC power supply.
• The main circuit power supply and the control power supply must be two

separate input power supplies.

• Power supplies must have double or reinforced insulation that conforms

to safety standards.

• Current limiting function is required for AC/DC converter which is used

for main circuit power supply. The current limiting specification must be
50A or less to prevent short-circuit current exceeds 50A under short cir-
cuit condition.

• External branch circuit protection must be provided in accordance with

the National Electrical Code and local codes.

When choosing molded-case circuit breakers and fuses for input power sup-
plies on the AC side, confirm the specifications of the input power supplies
and refer to this table.
Also, choose molded-case circuit breakers and fuses that meet the following
cutoff characteristics.
Cutoff characteristics (25

°C):

300% of the rated load input current, five

seconds min.

Does not cut off at the inrush current value

of the power supply.

* 1. Values with instantaneous maximum load.
* 2. Values with rated load.

SERVO-

PACK

Model

SGDV-

Main

Circuit

Power

Supply

Max.

Applica-

ble

Servo-

motor

Capacity

[W]

Power

Supply

Capacity

per

SERVO-

PACK

*1

[W]

Input Current Capacity

Rated Voltage

Main Circuit

Con-

trol

Cir-

cuit

*2

[A]

Fuse

[V]

MCCB

[V]

Continu-

ous

Rated

[A]

Instan-

taneous

Max.

[A]

100

V

200

V

400

V

100

V

200

V

400

V

1R7E

DC

24 V

11

108

2.0

5.5

0.3

250 600 240 480

DC

48 V

169

1.0

4.5

2R9E

DC

24 V

30

165

3.5

8.5

DC

48 V

411

2.0

10.5

Advertising
This manual is related to the following products: