F7 Safe-Off Control Board

+15VDC

= H6-06

F7 Safe-Off

Control Board

= H4-04

= H4-01

= H2-03

= H2-02

= H2-01

Fault Relay

BB = Hardware Baseblk

Chassis (Heatsink) Ground

3K

Ω

H6-01 =

Iso

+

250

Ω

S1-2

H3-09 =

H3-05 =

Auto Ref

24VDC

(Isolated)

-

+

BB1 = Hardware Baseblk

H1-01 =

H1-06 =

H1-05 =

H1-04 =

H1-03 =

H1-02 =

Run Rev

Run Fwd

2K

Ω

110

Ω

S1-1

-

+

RS485

/422

-

47Ω

N.O.

N.O.

N.O.

N.C.

N.O.

AC = 0V

Analog Common

-15VDC @ 20mA max

+15VDC @ 20mA max

3.3K

Ω

Safe-Off

Terminals

0 (Freq Ref)

(Output Freq) 02

0 (Freq Cmd A1 Bias)

02 (Manual Ref)

(Output Current) 03

(Output Freq) 02

24 (Ext Flt)

08 (Ext Baseblk)

06 (Jog Ref Sel)

03 (Ref Sel 1)

04 (Ref Sel 2)

14 (Clr Flt)

(at Zero Spd) 01

(at Set Spd) 02

(Running) 0