0 wiring, 0 i/o definitions – Yaskawa GPD515C-XXXX-CS006 User Manual

Page 2

Advertising
background image

Change

0 4/18/97

Page 2 of 6

Doc. No. 02Y00025-0422

Change 1 9/19/00

1.0 Wiring


Wire the incoming power, motor, and accessories and control wiring as specified in the GPD515
Technical Manual TM4515.



2.0 I/O Definitions


2.1 New Multi-Function Digital Input Settings
For Parameters H1-01 through H1-06.

Addition to Table 5-2 Multi-Function Input Terminal Data Settings (Section 5.32)

(2)

Data Function

Description

Availability

80 Disturbed

Waveform

Off

Open = Disturb function enabled
Closed = Disturb function disabled

V/f Only


2.2 New Multi-Function Digital Output Settings
For Parameters F5-01, F5-02 and H2-01 through H2-03.

Addition to Table 5-3 Multi-Function Output Terminal Data Settings (Section 5.33)

(2)

Data Function

Description

Availability

40

Disturb – Up Status

Closed during the accelerating period
when Disturb function is enabled

V/f Only

41

During Disturb

Closed when Disturb Function is
Active

V/f Only

2.3 New Multi-Function Analog Input Settings
For Parameters H3-05 and H3-09.
None.

2.4 New Multi-Function Analog Output Settings
For Parameters F4-01, F4-03, H4-01 and H4-04.
None.



(2)

GPD 515 Technical Manual TM4515