Yaskawa GPD515C-XXXX-CS006 User Manual
Page 6
                                    Advertising
                                    
                                        
                                    
                                
                                 
Change
0 4/18/97
Page 6 of 6
Doc. No. 02Y00025-0422
Change 1 9/19/00
Neg Slope Time
P1-04= 0.0 Sec
P1-04 Negative Slope Time
Setting Range:
0.0 to 120.0 Sec.
Factory Default:
0.0 Sec.
Modbus Address: 0583H 
 
Pos Slope Time
P1-05= 0.0 Sec
P1-05 Positive Slope Time
Setting Range:
0.0 to 120.0 Sec.
Factory Default:
0.0 Sec.
Modbus Address: 0584H 
 
These parameters determine the rate at which the speed reference will change during the 
“disturb” operation. P1-04 determines the decel time, and P1-05 determines the accel 
time. NOTE: The selected accel/decel rates (C1-01 through C1-08) are disabled during 
traverse operation. See Figure 1. 
 
 
 
5.0 New Monitors 
None.
 
6.0 New Alarm and Fault Codes 
None.
                                    Advertising
                    
                        
                    
                            
            
            
                            
                    See also other documents in the category Yaskawa Equipment:
                    
                        
                
            
        - Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 USB Copy Unit (2 pages)
- JVOP-181 (22 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)