Dedicated inputs, Smc–4000 installation guide, Item specifications – Yaskawa SMC-4000 User Manual

Page 18

Advertising
background image

14

SMC–4000 Installation Guide

Dedicated Inputs

Item

Specifications

Number of Input Points

Forward limit, Reverse limit, Home for all axes; and
Abort, Reset

Input Format

Sinking

Isolation

Optical

Voltage

24 VDC ± 20%

Current Rating (ON)

5.3 mA to activate

Input Impedance

2.2k

Operation Voltage

Logic 0 <5V
Logic 1 >15V

OFF Current

0.9 mA or less

Limit Switch Response
Time

OFF to ON: <0.5 ms
ON to OFF: <1.5 ms

X axis dedicated inputs shown. Other axes are the
same.

SMC–4000 CN5 Connector

Field Wiring

+24 VDC

Internal Circuitry

2.2k

30

17

4

33

26

Forward Limit Switch

Reverse Limit Switch

Home Input

Abort Input

Reset Input

0VDC

E

x

terna

l Inp

u

t

S

igna

l

Advertising