3 circuits and wiring specifications – Yaskawa VARISPEED-600 SERIES INVERTER User Manual

Page 30

Advertising
background image

31

3.3 CIRCUITS AND WIRING SPECIFICATIONS

Table 2

Circuits and Wiring Specifications

Name

Circuit

Termi-

nals

Wire

Size

AWG

(mm

2

)

Wire Type Terminal

Screw

Max.

Torque

lb⋅in

(N⋅m)

Braking Unit
(Models CDBR

2015B 2022B

Main

¨

¨

0

©

©

0

12−10

(3.5−5.5)

M4

13.3

(

−2015B, −2022B,

−4030B, −4045B,

−5037B)

Con-

trol

1 2 3
4 5 6

18−14

(0.75−2)

M4

13.3

(1.50)

Braking Unit
(Model CDBR

Main

¨

¨

0

©

©

0

10−8

(5.5−8) 600V

M5

21.7

(2.45)

(Model CDBR

−2045B, −4090B,

−5110B)

Con-

trol

1 2 3
4 5 6

18−14

(0.75−2)

600V

(High

Voltage)

*3

vinyl

M4

15.6

(1.76)

Braking Unit
(Model

CDBR 2110B

Main

¨

¨

0

©

©

0

4 (22)

8−6

(8−14)

*1

vinyl

sheathed

wire or

equivalent

M6

43.4

(4.90)

(

CDBR−2110B,

−4220B,−5300B)

Con-

trol

1 2 3
4 5 6

18−14

(0.75−2)

equivalent

M4

15.6

(1.76)

Braking Resistor

Unit

Main

B

P

12−10

(3.5−5.5)

M4

(M5)

*2

15.6 (1.76)

(21.7(2.45))

(Model LKEB−
j

)

Con-

trol

1

2

18−14

(0.75−2)

M4

15.6 (1.76)

*1 For wire size of 8−6 (8−14), use UL1283 heat−resistant vinyl−insulated wire or

equivalent.

*2 M4 for Models LKEB−20P7 to −27P5 or −40P7 to −4015.

M5 for Models LKEB−2011 to −2022 or −4018 to −4045.

*3 Models−5037B, −5100B, and −5300B can reach an operating voltage of 1040 VDC.

Please select wire which is suitable for the operating voltage.