3.4 WIRING PRECAUTIONS

(1) Wiring Leading−in Method

Lead in the wire through the knockout hole on the unit bottom. Since the
knockout hole is provided with a rubber bush, cut the rubber bush central
crosswise with a blade and lead the wire through.

(2) Separation from Signal Lines

Since strong noise component is superimposed on the braking resistor unit
and braking unit wiring, separate the units from signal lines which are weak
against noise.

(3) Wiring Distance

Wiring distance between the braking resistor unit and braking unit or braking
unit and inverter must be provided as shown in Fig. 13. Make sure to bundle
the wires between the units.

Braking Resistor

Unit

Braking Unit

Inverter

32.8ft

(10m)

or less

16.4ft

(5m)

or less

Fig. 13

Wiring Distance