8

••

The Smart Trac AC1 Digital Operator Engineer's Guide Smart Trac Digital Operator

Table 1. Digital Operator Indicators

Digital Operator Indicators

Indicator

Lamp

Function

DRIVE

Red light - programmable.

Typically lights (ON) when Smart Trac AC1 is in Drive mode of
operation.

FWD

Red light – programmable.

Typically lights (ON) when FWD motor direction is selected.

REV

Red light – programmable.

Typically lights (ON) when REV motor direction is selected.

REMOTE/

SEQ

Red light – programmable.

Typically ON when Smart Trac AC1 is operating from external RUN
and STOP signals

.

REMOTE/

REF

Red light – programmable.

Typically ON when Smart Trac AC1 operating by an external frequency
reference signal.

RUN

Red light – programmable.

Typically OFF when Smart Trac AC1 is in stopped condition. Typically
lights steadily (ON) when Run signal is active. It blinks after Stop
signal has been received and Smart Trac AC1 is ramping down.

STOP

Red light – programmable.

Typically, lights steadily (ON) at initial power-up. Typically blinks after
Run signal becomes active but frequency reference is zero. Typically off
when Smart Trac AC1 is controlling motor speed.