Cn3 connector pin assignments – Yaskawa SmartTrac DM6420 Multi I/O Card User Manual

Page 17

Advertising
background image


SMART TRAC DM6420 Multi I/O Card

Technical Manual Configuring the Smart Trac DM6420 Multi I/O Card

••

13

Table 2. Possible Multi I/O Base Address Settings.

Base Address Switch S1 Settings

Base Address

(Hexadecimal)

Base

Address

(Decimal)

Switch Setting

4

3

2

1

0x200

512

0

0

0

0

0x220

544

0

0

0

1

0x240

576

0

0

1

0

0x260

608

0

0

1

1

0x280

640

0

1

0

0

0x2A0

672

0

1

0

0

0x2C0

704

0

1

1

0

0x2E0

736

0

1

1

1

0x300

768

1

0

0

0

0x320

800

1

0

0

1

0x340

832

1

0

1

0

0x360

864

1

0

1

1

0x380

896

1

1

0

0

0x3A0

928

1

1

0

1

0x3C0

960

1

1

1

0

0x3E0

992

1

1

1

1

0 = Closed 1= Open Bold and Shaded value indicates default.

CN3 Connector Pin Assignments

A 50-pin connector CN3 permits use of eight differential analog inputs (or
sixteen single-ended analog inputs) and/or two analog outputs. You also make
any desired digital I/O connections at this connector.

Make sure all unused pins are not connected.