Connecting analog outputs, Connecting digital i/o – Yaskawa SmartTrac DM6420 Multi I/O Card User Manual

Page 20

Advertising
background image



Smart Trac DM6420 Multi I/O Card

16

••

Configuring the Smart Trac DM6420 Multi I/O Card Technical Manual


When using the differential mode:

1. Install a 10 kilohm resistor pack at location RN2 on the module to

provide a reference to ground for signal sources without a separate
ground reference.

2. Connect the high side of the analog input to the selected analog input

channel, AIN1+ through AIN8+,

3. Connect the low side of the input to the corresponding AIN- pin.

4. For signal sources with a separate ground reference, connect the ground

from the signal source to an ANALOG GND (pins 18 and 20-22 on
CN3).

Figure 7 shows how these connections are made.

Connecting Analog Outputs

To make an Analog Output connection, for each of the two D/A outputs:

1. Connect the high side of the device receiving the output to the AOUT

channel (CN3-17 or CN3-19).

2. Connect the low side of the device to an ANALOG GND (CN3-18 or

CN3-20).

Connecting Digital I/O

Digital connections consist of two eight-bit ports. Port 0 direction (Input or
Output) is bit-programmable. Port 1 direction (Input or Output) is byte (port)
programmable.

To make a Digital I/O connection:

1. Connect the high side of an external signal source or destination device

to the appropriate signal pin on the I/O connector.

2. Connected the low side to any DIGITAL GND.