Parameters deleted from standard software

The deleted parameters are not displayed on the digital operator. If any of these parameters are read via
Memobus communication, data of “0” is returned. These parameters cannot be written via Memobus, although
a normal response message will be returned.

No. Parameter

Description

002

Control mode selection

035

Setting/display unit of frequency reference selection

064

Frequency loss detection selection

065

Monitor output type

068

Analog frequency reference gain (CN2-1)

069

Analog frequency reference bias (CN2-1)

070

Analog frequency reference filter time constant (CN2-1)

071

Analog frequency reference gain (CN2-2)

072

Analog frequency reference bias (CN2-2)

073

Analog frequency reference filter time constant (CN2-2)

077

Multi-function analog input function

078

Multi-function analog input signal selection

079

Frequency reference bias

080

Carrier frequency selection

097

Overtorque detection function selection 2

106

Motor rated slip

108

Motor leakage inductance

109

Torque compensation voltage limiter

110

Motor no-load current

111

Slip compensation gain

112

Slip compensation time constant

113

Slip compensation during regenerative operation

128

Selection of PID control

129

PID feedback gain

130

Proportional gain (P)

131

Integral time (I)

132

Derivative time (D)

133

PID offset adjustment

134

Integral (I) upper limit

135

PID output primary delay time constant

136

PID feedback loss selection

137

PID feedback loss detection level

138

PID feedback loss detection time

139

Energy-saving control selection

140

Energy-saving coefficient K2

141

Energy-saving control voltage lower limit (At 60Hz)

142

Energy-saving control voltage lower limit (At 6Hz)

143

Power average time

144

Search operation voltage limit

145

Search operation voltage step (at 100%)

146

Search operation voltage step (at 5%)

150

Pulse train output scaling

158

Motor code

159

Energy-saving voltage upper limit (at 60Hz)

160

Energy-saving voltage upper limit (at 6Hz)

161

Search operation power detection hold width

162

Time constant of power detection filter

163

PID output gain

164

PID feedback value selection

165

Dynamic braking resistor overheat protection selection

166

Input phase loss detection level

167

Input phase loss detection time

168

Output phase loss detection level

169

Output phase loss detection time