1) preparation, 2) operating procedure – Yaskawa Sigma-5 User Manual: Operation of Digital Operator User Manual

Page 85

Advertising
background image

3.2 Operations

3-51

9

head1

3

Utility Function Mode

3.2.22 Display of Servomotor ID in Feedback Option Module (Fn01F)

This function displays ID information for servomotor and encoder in Feedback
Option Module connected to the SERVOPACK. If the option module is not con-
nected, “Not connect” will be displayed after the module name.

The following items can be displayed.

(1) Preparation

There are no tasks that must be performed before the execution.

(2) Operating Procedure

Use the following procedure.

ID

Items to be Displayed

Servomotor ID

• Servomotor model

• Servomotor order number

• Servomotor input voltage (V)

• Servomotor capacity (W)

• Servomotor rated current (Arms)

Encoder ID

• Encoder model

• Encoder serial number

• Encoder type/resolution (Two types of resolution display avail-

able: Number of bits and number of pulses/rev.)

Parameter File ID

• Parameter file source ID (14 characters)

• Parameter file version (4 digits hexadecimal display)

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main

menu for the utility function mode.
Use the

or

Key to move

through the list and select Fn01F.

2

Press the

Key.

The display changes to the Fn01F execu-

tion display.

The servomotor ID information is dis-
played. Use the

or

Key to

scroll left and right and to view other infor-

mation.

B B

− F U N C T I O N −

F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
F n 0 2 0 : S

− O r i g S e t

F n 0 3 0 : S o f t R e s e t

B B

− F B O p M o t I D −

M o t o r
S G M

− 0 4 A 3 1 2

R 1 0 4 1 9

− 5 1 1 − D K 5 0 0 0

2 0 0 V , 4 0 0 W

Serial number

Servomotor model

Input voltage

Capacity

Advertising