Assembly, Gb mt – Parkside PSBS 240 B2 User Manual

Page 57

Advertising
background image

57

GB MT

Assembly

Caution! Risk of injury!

- Ensure that you have sufficient

space in which to work, and that

you do not endanger other peo-

ple.

- Always fasten the device on to the

work surface with screws featuring

the sufficient length and thickness

in order to maintain control of the

device.

- All covers and protective devices

must be assembled properly be-

fore commissioning.

- Disconnect the mains plug before

changing the setting on the de-

vice.

Assemble/set spark

protection

1. Screw the spark protection (1)

using the adjusting screw (2) and

the nut (2a) on to the protective

hood (3).

To do so, you will need a screw-

driver and a ring spanner, used to

hold it in place.

2. Set the spark protection (1) with

the adjusting screw (2) so that the

distance between the grinding

disc (19) and the spark protection

is max. 2 mm (see small image).

Periodically readjust the spark pro-

tection in order to offset the wear

and tear of the grinding disc (dis-

tance max. 2 mm).

ing. Do not use coolants or the like.

• If you are tired or have consumed al-

cohol or tablets, do not work with the

device. Always have a break on time.

• Switch the device off and remove the

mains plug

- to loosen a blocked insertion tool,

- if the connection line is damaged or

entangled,

- in case of unusual sounds.

Residual risks

Even if properly operating and handling

this electric tool, some residual risks will

remain. Due to its construction and build,

this electric tool may present the following

hazards:

a) Lung damage, if suitable respiratory

protection is not worn.

b) Hearing damage, if suitable ear pro-

tection is not worn.

c) Damages to health due to

- touching the area of the grinding tool

which was not covered;

- the ejection of pieces from workpiece

or damaged grinding discs.

d) Damage to your health caused by

swinging your hands and arms when

operating the appliance for longer pe-

riods of time or if the unit is not held or

maintained properly.

Warning! During operation, this

electric tool generates an electro-

magnetic field which, under certain

circumstances, may impair the

functionality of active or passive

medical implants. To reduce the risk

of serious or lethal injuries, we rec-

ommend that persons with medical

implants consult their doctor and the

manufacturer of their medical im-

plant before operating the machine.

Advertising