Command 3 - Sample and Trigger Setup
Sampling Interval
Number of Samples
Record Time
0.00002
Number of seconds
1 to
Number of samples
0
Off
to 16000
120000
*1
Absolute time recording
(*0.1)
(*100)
2
Relative time recording
Trigger Souce
Trigger Threshold
Trigger Edge
Clock Source
*1
[START/STOP] key
–––
–––
*0
Timer (Sample interval)
2 or 5
CH1
Sampled Values
0
Falling edge
10
Same as Trigger Source
3 or 6
CH2
• Corrected values when Command 4
*1
Rising edge
(1 to 5)
4 or 7
CH3
2
Rising and falling edge
8
DIG IN Clock
–––
9
DIG IN 8-bit data
0–255 (D7–D0)
–––
(*1)
10
Microphone
Sampled Values ±1.5V
0
Fallig edge
*1
Rising edge
2
Rising and falling edge
11
SONIC
Distance
0
Falling edge
• Unit depends on Command 1.
1
Rising edge
(*0.05)
*2
Difference with previous value is below
3
Difference with previous value is above
–––
20
Count down
Count Number (sec)
–––
1 to 10 (*10)
–1
Command 8
–––
–––
{ 3, Sampling Interval, Number of Samples, Record Time, Trigger Source, Trigger Threshold, Trigger Edge, Clock Source }