Command 4 - conversion equation setup, Command 5 - data range setup – Casio EA-200 Technical Reference User Manual

Page 7

Advertising
background image

– 7 –

Command 4 - Conversion Equation Setup

{ 4, Equation Number, Equation Type, Number Format, Constants }

Equation Number

Equation Type

Number Format

Constants

* 0

Clear All equations.

* 0

Clear equation selected by the equation number parameter.

–––

–––

1

Equation 1 (Channel 1)

1

Polynomial

K

0

+K

1

X+K

2

X

2

+...+K

n

X

n

*

1

* 0

Standard

K

0

( , K

1

, ..., K

9

) *

3,4

2

Equation 2 (Channel 2)

2

Mixed polynomial

K

–m

X

–m

+...+K

–1

X

–1

+K

0

+K

1

X+......+K

n

X

n

*

2

10

Integer part (Decimal part cut off.)

K

–4

( , ..., K

–1

, K

0

, K

1

, ..., K

5

) *

3,4

3

Equation 3 (Channel 3)

3

Power

K

0

X

(K1)

+K

2

4

Modified power

K

0

K

1(X)

+K

2

5

Logarithmic

K

0

+K

1

In(X)

6

Modified logarithmic

K

0

+K

1

In(1/X)

7

Exponential

K

0

e

(K

1

X)

+K

2

K

0

( , K

1

, K

2

, K

3

) *

3,4

8

Modified exponential

K

0

e

(K

1

/X)

+K

2

9

Geometric

K

0

X

(K

1

X)

+K

2

10

Modified geometric

K

0

X

(K

1

/X)

+K

2

11

Reciprocal logarithmic [K

0

+K

1

In(K

2

X)]

–1

+K

3

12

Steinhart-Hart model [K

0

+K

1

(In 1000X)+K

2

(In 1000X)

3

]

–1

+ K

3

4

Equation 4 (SONIC channel)

* 0

Clear equation 4.

Unit

Temperature

1

Temperature used by distance conversion expression

* 0

°C (Celsius)

Temperature

1

°F (Fahrenheit)

( *20)

2

°C (Celsius)

3

K (kelvin)

4

°R (Rankin)

Channel Select

Data Select

Data Begin

Data End

Step

K

FFT Samples

* 0

Current send channel

* 0

Raw data

1 to 120000

1 to 120000

Data Range Steps

(*255)

1 to 13: Samples used

1

Channel 1

1

d/dt

(*1)

* 0: Last sample

–1: Data range number / K

(*6) 2

n

(2–8192)

2

Channel 2

2

d

2

/dt

2

(*1)

3

Channel 3

10

FFT-Real

4

SONIC channel

11

FFT-Imaginary

5

DIG IN channel

6

Recorded time data

10

Microphone

Command 5 - Data Range Setup

*1

Polynomial: Input constants in sequence, from n = 0 to 9.

*2

Mixed polynomial: Input constants in sequence from m = 4 to 1, and n = 0 to 5.

*3

Input of zero for constants can be skipped if all remaining constants are not used.

*4

Input 0 for constants that are not used.

When the conversion result of the “conversion equation” selected by Command 4 causes an overflow, the EA-200 sends a result of zero (0) to the calculator.

{ 5, Channel Select, Data Select, Data Begin, Data End, Step, K (, FFT Samples) }