Lanview leds -3, Table 4-1 – Enterasys Networks A2H124-24FX User Manual
Page 65

Using LANVIEW
SecureStack A2 Installation Guide 4-3
Table 4-1 LANVIEW LEDs
LED
Color
State
Recommended Action
CPU
Off
Power disconnected.
If the LED remains off after connecting AC
power or DC power from an RPS, check
the following:
1. Make sure there is power at the power
source (AC source and RPS if
applicable).
2. Replace the power cord with a known
good one or check the continuity of the
power cord.
3. If the SecureStack A2 still does not
power up, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
Red
Solid. Boot-up failed.
If the LED remains red for several
minutes, the system may have a fatal
error. Contact Enterasys Networks for
technical support.
Blinking. Diagnostics have
failed.
Contact Enterasys Networks for technical
support.
Amber
Solid. Diagnostics are running. If the LED remains amber for more than
several minutes, contact
Enterasys Networks for technical support.
Blinking. Code image is being
downloaded, or the Manager
switch is copying its
configuration to the other
members in the stack (this
happens automatically every
15 minutes and every time the
“save config” command is
executed.
None.
Green
Solid. System is fully
functional.
None.
Blinking. Boot-up in process.
None.