C-11499 instruction cara owner's manual2, Initial installation – Enviro Cara User Manual

Page 21

Advertising
background image

21

Woodscrews

Wall Thimble

Strap

Sheet metal

screws

Fold strap

here

1

1

/

4

"

(3.2cm)

Figure 33: Installing Decorative Wall Thimble.

10"

(254mm)

10"

(254mm)

Figure 32: Wall Framing Hole for

Horizontal Installation.

the outside, on black pipe. They may be located by examining the inside of the female ends as shown

in Figure 31.

Notes:
(a) Twist-lock procedure: four (4) indentations, located on the female end of the pipes and fittings, are

designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe

indentations so they match and slide into the four entry slots on the male end.
(b) Horizontal runs of vent pipe must be supported every 36” (915mm). Wall straps are available for this

purpose, also when running horizontal pipe minimum clearances to combustibles must be maintained;

2” (51mm) at top, 1½” (38mm) at sides, 1½” (38mm) at bottom.
3.
With the pipe attached to the stove in the correct location,

mark the wall for a 10” (25.4cm) x 10” (25.4 cm) square hole

(refer to Figure 32). The center of the square hole should

match the center line of the horizontal pipe. Cut and frame the

10” (25.4cm) x 10” (25.4cm) hole in the exterior wall where

the vent will be terminated. Refer to Figure 23 and Table 7. If

the wall being penetrated is constructed of non-combustible

material i.e. masonry or concrete, a 7” (17.8cm) hole is

acceptable.

4. Position the horizontal vent termination in the center of the

10” (25.4cm) x 10” (25.4cm) hole, and attach to the exterior

wall with the four screws provided. Before attaching the vent

termination to the exterior wall, run a bead of non-hardening

mastic around the edges, so as to make a seal between the

termination and the wall. The arrow on the vent termination

should be pointing up, insure that the proper clearances to

combustible materials are maintained.

5. Before connecting the horizontal run of the vent pipe to the

vent termination, slide the black decorative wall thimble cover over the vent pipe.

6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the

cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a

minimum of 1¼” (3.2cm) overlap. Secure the connection between the vent cap pipe and the vent cap

Initial Installation

QUALIFIED INSTALLERS ONLY

by attaching the two sheet

metal straps extending from

the vent cap assembly into

the outer wall of the vent

pipe. Use the two sheet

metal screws provided

to connect the straps to

the vent pipe. Bend any

remaining portion of the

sheet metal straps back

towards the vent cap, so

the decorative wall thimble

will conceal it (see left

image in Figure 33).

Advertising