Initial installation, Qualified installers only e – Enviro Cara User Manual

Page 30

Advertising
background image

Initial Installation

QUALIFIED INSTALLERS ONLY

e

lectrical

r

equirements

f

or

g

as

V

alVe

and

o

ptional

B

lower

:

The ENVIRO CARA will operate without electrical power. This model has a millivolt gas control, which

uses the pilot flame to generate enough electricity to operate the main burners. The appliance, when

equipped with a blower, must be electrically connected and grounded in accordance with local codes or

in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY

STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70

in the U.S. When installing the Optional Remote Control System for the valve and the blower, refer also

to the r

emote

C

ontrols

section, and to Figure 4.

WARNING: Electrical grounding instructions. This appliance is equipped with a three-prong (grounding)

plug for your protection against shock hazard, and must be plugged directly into a properly grounded

three-prong outlet.

Figure 50: Gas Control Valve and Optional Thermostat Wiring.

COOL / HEAT
PROGRAM

DOWN

UP

70 ° F

Optional

Remote

Control

ON/OFF

Burner Switch

Purple

Thermocouple

Blue

Thermopile

Grey

Inlet

Pressure

Tap

Gas Control

Valve

Manifold

Pressure Tap

Pilot Adjustment

Screw

Optional

Wall Switch

Optional

Thermostat

Table 10: Recommended Thermostat

Wire Size.

Wire Size

Max. Length

14 gauge

100 ft (30.48 m)

16 gauge

60 ft (18.29 m)

18 gauge

40 ft (12.00 m)

20 gauge

25 ft (7.62 m)

22 gauge

18 ft (5.49 m)

CAUTION: Label all wires prior

to disconnection when servicing

controls. Wiring errors can cause

improper and dangerous operation.

Verify proper operation after

servicing.

Figure 51: Wiring Diagram for Electric Fan.

DO NOT cut or remove the grounding prong

from this plug.

ELECTRICAL INFORMATION:
Canadian Installations

The venting system must be installed in

accordance with the current CSA B149

installation code and/or local codes having

jurisdiction.
U.S.A. Installations

The venting system must be installed in

accordance with the current National Fuel

Gas Code, ANSI Z223.1, and/or local codes

having jurisdiction.

Rheostat

Snap Disk N/O

Black

Green/White

Black

White

Fan

Power

Cord

Black

Black

Black

Green/Yellow

30

Advertising