Kichler 15165 User Manual

Kichler Lighting

Advertising
background image

SAFETY INSTRUCTIONS

READ THIS FIRST

KEEP THESE INSTRUCTIONS

This fixture is intended for installation in accordance with the National

Electric Code (NEC) and Local code specifications. Failure to adhere to

these codes and instructions may result in serious injury and/or property

damage and will void the warranty.

1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool,

spa or fountain.

2) This fixture is to be used only with a power unit (transformer) rated a

maximum of 300 W (25 AMPS) 15 volts.

3) The #18 ga. fixture wire is not intended for direct burial.

4) Direct burial rated wire is to be buried a minimum of 6” (152mm) beneath

the surface of the ground.

NOTE: If additional Direct Burial wire is needed, contact your local Kichler

®

landscape distributor.

• 8 GA wire can be purchased in length of 250’ (76 M), 15503-BK.

• 10 GA wire can be purchased in length of 250’ (76 M), 15504-BK.

• 12 GA wire can be purchased in lengths of 100’ (30 M), 15501-BK; 250’

(76 M), 15502-BK; 500’ (152M), 15505-BK; and 1000’ (304 M), 15506-BK.

5) Fixture shall not use a tungsten halogen lamp unless the fixture is marked

for use with such lamps.

6) Wiring connections must be made with approved/listed wire connection

device(s) suitable for the application. Do not exceed manufacturers’ wiring

combination specifications for size and quantity of conductors.

For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page

Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page

Date Issued: 12/2/11

IS-15165-US

Quic Disc

WIRING INSTRUCTIONS

Turn off power.

The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are met:

• Wiring is to be protected by routing close to the fixture or accessory or secured to a building structure such as house or deck.

• 18 GA fixture wiring is to be cut off so that it is attached to the connector within 6 inches of the fixture or building structure.

• If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA fixture wire is to be buried.

The Quic Disc

connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA supply wire.

Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc

or place the 12 gauge supply wire across the area marked 12 GA

on Quic Disc

.

Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc

. After the wires are in place, connecta the top of the Quic

Disc

to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc

, and the screw is tightened

all the way down.

The copper contacts will automatically pierce the wires’ insulation. Excess 18 GA fixture wire that sticks out the end of the Quic Disc

is to be cut off.

Make no other wiring connections to the 18 GA fixture wire.

1) Establish center of post or a center line on mounting surface.

2) Drill two 1/8” (3mm) pilot holes into mounting surface on center line. Fig. 1

can be used as a template.

3) Using bottom inside edge of fixture as a depth gage, drive screws into

pilot holes until bottom of screw heads almost touch bottom inside edge of

fixture. See fig. 2.

4) Slide slot at bottom of fixture over bottom screw.

5) Slip large portion of keyhole over top screw.

6) Push fixture down so top screw is in smaller portion of keyhole.

7) Secure in place by tightening screws.

FIXTURE

ARTEFACTO

SCREW

TORNILLO

BOTTOM INSIDE EDGE

BORDE INTERNO

INFERIOR

SLOT

MUESCA

KEYHOLE

BOCALLAVE

1 1/8”

(29MM)

FIGURE 1

FIGURA 1

FIGURE 2

FIGURA 2

Advertising