MOUNTING STRAP

ABRAZADERA DE MONTAJE

1) Pass wire through threaded pipe. Screw end of threaded
pipe with hexnut into coupling on top of fixture body.
2) Pass wire through tube. Lower tube down over threaded pipe.
3) Pass wire through hole in check ring. Pass hole in check ring
over end of threaded pipe. Set check ring on top of tube.
4) Pass wire through hole in top trim. Pass hole in top trim over
end of threaded pipe. Set top trim on top of check ring.
5) Pass wire through coupling. Thread coupling onto threaded pipe.
6) Pass wire from fixture through stem and screw stem into
coupling on top of fixture body.
NOTE: Thread locking compound must be applied to all
stem threads as noted with symbol (3) to prevent accidental
rotation of fixture during cleaning, relamping, etc.
7) Pass fixture wire through remaining stems and screw stems
together.
8) If using swivel for sloped ceilings, pass fixture wire through
swivel and thread swivel onto top of last stem.
9) Thread small threaded pipe into end of swivel.
10) Pass threaded pipe on end of swivel up through hole in
canopy.
11) Slip large flat washer then lockwasher over end of threaded
pipe protruding from inside of canopy. Thread hexnut onto
threaded pipe. Tighten hexnut to secure swivel to canopy.
NOTE DIRECTION OF SWIVEL IN ACCORDANCE WITH
CEILING.
12) If not using swivel, thread small threaded pipe into end of
last stem.
13) Pass threaded pipe on end of stem up through hole in
canopy.
14) Slip lockwasher over end of threaded pipe protruding from
inside canopy. Thread hexnut onto threaded pipe. Tighten
hexnut to secure stem to canopy.
15) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your

home. Place the main power switch in the “OFF”

position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker

switch(s), that control the power to the fixture or room

that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture

to be replaced has a switch or pull chain, place those in

the “OFF” position.

16) Find the appropriate threaded holes on mounting strap.
Assemble mounting screws into threaded holes.
17) Attach mounting strap to outlet box. (Screws not provided).
Mounting strap can be adjusted to suit position of fixture.
18) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a

hole and two raised dimples. Wrap ground wire from

outlet box around green ground screw, and thread into

hole.

B) On fixtures where a cupped washer is provided. Attach

ground wire from outlet box under cupped washer and

green ground screw, and thread into mounting strap.

If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector.
(Not provided.) After following the above steps. Never
connect ground wire to black or white power supply wires.

19) Make wire connections (connectors not provided.) Reference
chart below for correct connections and wire accordingly.

GREEN GROUND

SCREW

CUPPED

WASHER

A

B

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

(NOT PROVIDED)

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

Date Issued: 10/12/12

IS-43262-US

CANOPY

ESCUDETE

STEM

VÁSTAGO

KNURL KNOB

PERILLA ESTRADA

3

SWIVEL

UNIÓN GIRATORIA

3

3

20) Push fixture to ceiling, carefully passing mounting screws
through holes in canopy.
21) Thread knurl knobs onto mounting screws. Tighten knurl
knobs to secure fixture to ceiling.
22) Thread short end of long threaded pipe with hexnut into

coupling on bottom of fixture body.

23) Pass hole in flat washer over end of threaded pipe. Pass hole

in rubber washer over end of threaded pipe.

24) Raise inner glass shade up to fixture. Fit inner glass shade

inside cage.

25) Pass hole in inner glass shade over end of threaded pipe.
26) Slip hole in rubber washer over end of threaded pipe. Slip

hole in flat washer over end of threaded pipe.

27) Screw hexnut onto threaded pipe. Tighten hexnut up against

flat washer.

28) Pass hole in bottom trim over end of threaded pipe.
29) Screw finial onto end of threaded pipe. (DO NOT over tighten.)

FINIAL

REMATE

RUBBER WASHER

ARANDELA DE CAUCHO

FLAT WASHER

ARANDELA PLANA

THREADED PIPE

TUBO ROSCADO

HEXNUT

TUERCA HEXAGONAL

BOTTOM TRIM

GUARNICIÓN INFERIOR

INNER GLASS SHADE

PANTALLA DE VIDRIO

INTERIOR

CAGE

JAULA

TUBE

TUBO

FLAT WASHER

ARANDELA PLANA

RUBBER WASHER

ARANDELA DE CAUCHO

THREADED PIPE

TUBO ROSCADO

COUPLING

ACOPLAMIENTO

SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.

CHECK RING

ANILLO DE SEGURIDAD

TOP TRIM

GUARNICIÓN SUPERIOR

Advertising