17) Make wire connections (connectors not provided). Reference

chart below for correct connections and wire accordingly.

18) Push fixture to ceiling, carefully passing mounting screws

through holes in canopy.

19) Thread knurl knobs onto mounting screws. Tighten knurl

knobs to secure fixture to ceiling.

20) Lower glass down over socket. Pass hole in glass over socket.
21) Thread socket ring onto socket. Tighten socket ring to hold

glass in place. (DO NOT over tighten.)

22) Insert recommended bulb. CAUTION: DO NOT touch bulb
with bare hands. If this happens, clean bulb with denatured
alcohol and a lint free cloth.
23) Slip glass sleeve over bulb.

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

IMPORTANT SAFETY INSTRUCTIONS

LIGHTED BULB IS HOT!

WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turn off and allow to cool before replacing bulb.
• Bulb gets HOT QUICKLY! Contact switch only when turning off.
• DO NOT remain in light if skin feels warm. (Light is intense,
may cause “sunburn”)
• DO NOT look directly at lighted bulb.
• Keep materials away from bulb that may burn.
• Use ONLY with wattage specified or lower.
• DO NOT touch bulb at any time, use a soft cloth. Oil from skin
may damage bulb.
• DO NOT operate fixture with missing or damaged glass.

1) Pass fixture wire through long threaded pipe.
2) Screw end of long threaded pipe with hexnut into coupling

on top of fixture body.

3) Pass fixture wire through tube. Lower tube down over

threaded pipe.

4) Pass fixture wire through hole in top cap. Pass hole in top

cap over end of threaded pipe. Set top cap on top of tube.

5) Pass fixture wire through coupling. Screw coupling onto end

of threaded pipe.

6) Pass wire through stem and screw stem to coupling on top

of fixture body. NOTE: Thread locking compound must be

applied to all stem threads as noted with symbol (3) to prevent

accidental rotation of fixture during cleaning, relamping, etc.

7) Pass wire through remaining stems and screw stems
together.
8) Thread one small threaded pipe into end of each small loop.
9) Attach small loop to end of last stem.
10) Pass threaded pipe at end of second small loop through

hole in canopy.

11) Slip lockwasher over threaded pipe protruding from inside of

canopy and screw hexnut onto threaded pipe.

12) Attach chain link to small loop at end of stem and to loop on
canopy.
13) TURN OFF POWER.

IMPORTANT: Before you start, NEVER attempt any work

without shutting off the electricity until the work is done.

a) Go to the main fuse, or circuit breaker, box in your

home. Place the main power switch in the “OFF”

position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker

switch(s), that control the power to the fixture or room

that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture

to be replaced has a switch or pull chain, place those in

the “OFF” position.

14) Find the appropriate threaded holes on mounting strap.

Assemble mounting screws into threaded holes.

15) Attach mounting strap to outlet box. (Screws not provided).

Mounting strap can be adjusted to suit position of fixture.

16) Grounding instructions: (See Illus. A or B).

A) On fixtures where mounting strap is provided with a

hole and two raised dimples. Wrap ground wire from

outlet box around green ground screw, and thread into

hole.

B) On fixtures where a cupped washer is provided. Attach

ground wire from outlet box under cupped washer and

green ground screw, and thread into mounting strap.

If fixture is provided with ground wire. Connect fixture

ground wire to outlet box ground wire with wire connector

(not provided.) after following the above steps. Never

connect ground wire to black or white power supply wires.

Date Issued: 10/4/13

IS-43364-US

GREEN GROUND

SCREW

CUPPED

WASHER

A

B

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

(NOT PROVIDED)

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.

We’re here to help

866-558-5706

Hrs: M-F 9am to 5pm EST

MOUNTING STRAP

ABRAZADERA DE MONTAJE

CANOPY

ESCUDETE

FIXTURE BODY

CUERPO DEL ARTEFACTO

KNURL KNOB

PERILLA ESTRADA

SMALL LOOP

ARGOLLA PEQUEÑA

CHAIN LINK

ESLABÓN DE CADENA

3

STEM

VASTAGO

GLASS

VIDRIO

BULB

BOMBILLA

GLASS SLEEVE

CAMISA DE VIDRIO

COUPLING

ACOPLAMIENTO

TOP CAP

TAPA SUPERIOR

TUBE

TUBO

LONG THREADED PIPE

TUBO ROSCADA LARGO

SOCKET RING

ANILLO DEL

CASQULLO