Kichler 43682 User Manual

Kichler Lighting

Advertising
background image

MOUNTING STRAP

ABRAZADERA DE MONTAJE

NOTE: Height of fixture must be adjusted before fixture is
mounted to ceiling.
1) To adjust the length of the cord to achieve the desired

height of the mounted fixture: Loosen threaded stud on

strain relief on canopy. Carefully pull cord up into canopy to

shorten the height of fixture or carefully pull cord down to

lengthen the height of fixture. When desired height is

achieved, tighten threaded stud on strain relief.

2) TURN OFF POWER.

IMPORTANT: Before you start, NEVER attempt any work

without shutting off the electricity until the work is done.

a) Go to the main fuse, or circuit breaker, box in your

home. Place the main power switch in the “OFF” position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker

switch(s), that control the power to the fixture or room

that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture

to be replaced has a switch or pull chain, place those in

the “OFF” position.

3) Find the appropriate threaded holes on mounting strap.

Assemble mounting screws into threaded holes.

4) Attach mounting strap to outlet box. (Screws not provided).

Mounting strap can be adjusted to suit position of fixture.

5) Grounding instructions: (See Illus. A or B).

A) On fixtures where mounting strap is provided with a

hole and two raised dimples. Wrap ground wire from

outlet box around green ground screw, and thread into hole.

B) On fixtures where a cupped washer is provided. Attach

ground wire from outlet box under cupped washer and

green ground screw, and thread into mounting strap.

If fixture is provided with ground wire. Connect fixture

ground wire to outlet box ground wire with wire connector.

(Not provided.) After following the above steps. Never

connect ground wire to black or white power supply wires.

6) Make wire connections (connectors not provided.) Reference

chart below for correct connections and wire accordingly.

7) Push fixture to ceiling, carefully passing mounting screws

through holes in canopy.

8) Thread knurl knobs onto mounting screws. Tighten knurl

knobs to secure fixture to ceiling.

9) Raise shade up to fixture. Pass hole in shade over socket.
10) Thread socket ring onto socket. Tighten socket ring to

secure shade in place. (DO NOT over tighten.)

GREEN GROUND

SCREW

CUPPED

WASHER

A

B

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

(NOT PROVIDED)

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

Date Issued: 10/24/14

IS-43682-US

CANOPY

ESCUDETE

KNURL KNOB

PERILLA ESTRADA

SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.

We’re here to help

866-558-5706

Hrs: M-F 9am to 5pm EST

SHADE

PANTALLA

THREADED STUD

ESPÁRRAGO

ROSCADO

SOCKET RING

ANILLO DEL CASQUILLO

CORD

CORDÓN

STRAIN RELIEF

ALIVIO DE LA TENSIÓN

SOCKET

CASQUILLO

Advertising