MOUNTING STRAP

ABRAZADERA DE

MONTAJE

SEMI FLUSH INSTALLATION INSTRUCTIONS

1) Screw end of threaded pipe into coupling on top of fixture body.

2) Lower tube down over threaded pipe.

3) Pass hole in check ring over end of threaded pipe. Set check ring on

top of tube.

4) Pass hole in canopy over end of threaded pipe. Set canopy on top of

check ring.

5) Slip lockwasher over end of threaded pipe. Thread hexnut onto

threaded pipe.

6) Follow steps #13-29 in Stem Drop Installation Instructions.

STEM DROP INSTALLATION INSTRUCTIONS

1) Pass fixture wire through long threaded pipe.

2) Screw end of long threaded pipe into coupling on top of fixture body.

3) Lower tube down over threaded pipe.

4) Pass hole in check ring over end of threaded pipe. Set check ring on

top of tube.

5) Screw coupling onto end of threaded pipe.

6) Pass wire from fixture though stem and screw stem to top of fixture.

NOTE: Thread locking compound must be applied to all stem

threads as noted with symbol (3) to prevent accidental rotation of fixture

during cleaning, relamping, etc.

7) Pass fixture wire through remaining stems and screw stems together.

8) Thread one small threaded pipe into end of each small loop.

9) Attach small loop to end of last stem.

10) Pass threaded pipe at end of second small loop through hole in canopy.

11) Slip lockwasher over threaded pipe protruding from inside of canopy

and screw hexnut onto threaded pipe.

12) Attach chain link to small loop at end of stem and to loop on canopy.

13) TURN OFF POWER.

IMPORTANT: Before you start, NEVER attempt any work without

shutting off the electricity until the work is done.

a) Go to the main fuse, or circuit breaker, box in your home. Place

the main power switch in the “OFF” position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker switch(s),

that control the power to the fixture or room that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture to be

replaced has a switch or pull chain, place those in the “OFF”

position.

14) Find the appropriate threaded holes on mounting strap. Assemble

mounting screws into threaded holes.

15) Attach mounting strap to outlet box. (Screws not provided). Mounting

strap can be adjusted to suit position of fixture.

16) Grounding instructions: (See Illus. A or B).

A) On fixtures where mounting strap is provided with a hole and two

raised dimples. Wrap ground wire from outlet box around green

ground screw, and thread into hole.

B) On fixtures where a cupped washer is provided. Attach ground

wire from outlet box under cupped washer and green ground

screw, and thread into mounting strap.

If fixture is provided with ground wire. Connect fixture ground wire to

outlet box ground wire with wire connector. (Not provided.) After

following the above steps. Never connect ground wire to black or

white power supply wires.

17) Make wire connections (connectors not provided.) Reference chart

below for correct connections and wire accordingly.

18) Push fixture to ceiling, carefully passing mounting screws through holes

in canopy.

19) Secure fixture to ceiling with threaded balls.

20) Insert recommended bulbs.

21) Screw short end of threaded pipe with bead into coupling at bottom

of fixture.

22) Slip flat washer then rubber washer over end of threaded pipe.

23) Raise glass up to fixture. Pass hole in glass over end of threaded pipe.

24) Slip remaining rubber washer then flat washer over end of threaded

pipe.

25) Screw hex coupling onto threaded pipe. Screw short threaded pipe

into end of hex coupling.

26) Pass hole in large washer over end of threaded pipe.

27) Raise shade up to fixture. Place shade over glass.

28) Raise glass diffuser up to fixture. Pass hole in glass diffuser over end

of threaded pipe.

29) Screw finial onto end of threaded pipe. (DO NOT over tighten.)

GREEN GROUND

SCREW

CUPPED

WASHER

A

B

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

(NOT PROVIDED)

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

Date Issued: 7/27/12

IS-65388-US

CANOPY

ESCUDETE

STEM

VÁSTAGO

KNURL KNOB

PERILLA ESTRADA

3

SMALL LOOP

ARGOLLA PEQUEÑA

CHAIN LINK

ESLABÓN DE CADENA

3

THREADED PIPE

TUBO ROSCADO

FINIAL

CAPUCHON

HEX COUPLING

ACOPLAMIENTO

FLAT WASHER

ARANDELA PLANA

FLAT WASHER

ARANDELA PLANA

RUBBER WASHER

ARANDELA DE CAUCHO

GLASS DIFFUSER

DIFUSOR DE VIDRIO

STEM MOUNT INSTALLTION

INSTALACIÓN DEL VÁSTAGO DE MONTAJE

SEMI FLUSH INSTALLATION

INSTALACIÓN DEL SEMI-RAS

MOUNTING STRAP

ABRAZADERA DE MONTAJE

CANOPY

ESCUDETE

KNURL KNOB

PERILLA ESTRADA

SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.

COUPLING

ACOMPLAMIENTO

HEXNUT

TUERCA HEXAGONAL

LOCKWASHER

ARANDELA DE

SEGURIDAD

SHADE

PANTALLA

TUBE

TUBO

CHECK RING

ANILLO DE SEGURIDAD

HEXNUT

TUERCA HEXAGONAL

LOCKWASHER

ARANDELA DE SEGURIDAD

TUBE

TUBO

CHECK RING

ANILLO DE SEGURIDAD

THREADED PIPE

TUBO ROSCADO

RUBBER WASHER

ARANDELA DE CAUCHO

LARGE WASHER

ARANDELA GRANDE

GLASS

VIDRIO

SHORT

THREADED

PIPE

TUBO

ROSCADO

CORTA

THREADED PIPE

TUBO ROSCADO