1) TURN OFF POWER.

IMPORTANT: Before you start, NEVER attempt any work

without shutting off the electricity until the work is done.

a) Go to the main fuse, or circuit breaker, box in your

home. Place the main power switch in the “OFF” position.

b) Unscrew the fuse(s), or switch “OFF” the circuit breaker

switch(s), that control the power to the fixture or room

that you are working on.

c) Place the wall switch in the “OFF” position. If the fixture

to be replaced has a switch or pull chain, place those in

the “OFF” position.

2) Find the appropriate threaded holes on mounting strap.

Assemble mounting screws into threaded holes.

3) Attach mounting strap to outlet box. (Screws not provided).

Mounting strap can be adjusted to suit position of fixture.

4) Grounding instructions: (See Illus. A or B).

A) On fixtures where mounting strap is provided with a

hole and two raised dimples. Wrap ground wire from

outlet box around green ground screw, and thread into

hole.

B) On fixtures where a cupped washer is provided. Attach

ground wire from outlet box under cupped washer and

green ground screw, and thread into mounting strap.

If fixture is provided with ground wire. Connect fixture

ground wire to outlet box ground wire with wire connector.

(Not provided.) After following the above steps. Never connect

ground wire to black or white power supply wires.

5) Make wire connections (connectors not provided.) Reference

chart below for correct connections and wire accordingly.

6) Push fixture to wall, carefully passing mounting screws

through holes in canopy.

7) Thread threaded balls onto mounting screws. Tighten

threaded balls to secure fixture to wall.

8) Insert recommended bulb.

9) Lower glass down over bulb. Fit bottom of glass into cup of

fixture.

INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/

OR IN WET LOCATIONS.

10) Mounting surface should be clean, dry, flat and 1/4” larger

that the canopy on all sides. Any gaps between the mounting

surface and canopy exceeding 3/16” should be corrected

as required.

11) With silicone caulking compound, caulk completely around

where back of canopy meets the wall surface to prevent

water from seeping into outlet box.

1) APAGAR LA ALIMENTACIÓN DE ENERGIE ELÈTRICA.

IMPORTANTE: Antes de comenzar, NUNCA trate de trabajar

sin antes desconectar la corriente hasta que el trabajo se

termine.

a) Vaya a la caja principal de fusibles, o interruptor o caja

de circuitos de su casa. Coloque el interruptor de la

corriente principal en posición de apagado “OFF”.

b) Desatornille el (los) fusible (s), o coloque el interruptor o

interruptores del breaker en posición de apagado

“OFF”, que controla (n) la corriente hacia el artefacto o

habitación donde está trabajando.

c) Coloque el interruptor de pared en posición de apagado

“OFF”. Si el artefacto que se va a reemplazar tiene un

interruptor o cadena que se jala, colóquelos en la posición

de apagado “OFF”.

2) Encontrar los agujeros roscados correctos en la abrazadera

de montaje. Instalar los tornillos de montaje en los agujeros

roscados.

3) Unir la abrazadera de montaje a la caja de conexiones. (No

se proveen tornillos). La abrazadera de montaje puede

ajustarse para acomodar la posición del artefacto.

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

Date Issued: 3/22/13

IS-49006-US

MOUNTING STRAP

PLANCHA PARA

MONTAR

THREADED BALL

BOLA ROSCADO

GREEN GROUND

SCREW

CUPPED

WASHER

A

B

OUTLET BOX

GROUND

FIXTURE

GROUND

DIMPLES

WIRE CONNECTOR

(NOT PROVIDED)

OUTLET BOX

GROUND

GREEN GROUND

SCREW

FIXTURE

GROUND

4) Instrucciones de conexión a tierra solamente para los

Estados Unidos. (Vea la ilustracion A o B).

A) En las lámparas que tienen el fleje, de montaje con un

agujero y dos hoyuelos realzados. Enrollar el alambre a

tierra de la caja tomacorriente alrededor del tornillo

verde y pasarlo por el aquiero.

B) En las lámparas con una arandela acopada. Fijar el

alambre a tierra de la caja tomacorriente del ajo de la

arandela acoada y tornillo verde, y paser por el fleje de

montaje.

Si la lámpara viene con alambre a tierra. Conecter el

alambre a tierra de la lámpara al alambre a tierra de la caja

tomacorriente con un conector de alambres. (No incluido)

Espués de seguir los pasos anteriores. Nunca conectar el

alambra a tierra a los alambres eléctros negro o blanco.

5) Haga les conexiones de los alambres (no se proveen los

connectores.) La tabla de referencia de abajo indica las

conexiones correctas y los alambres correspondientes.

6) Empuje el artefacto hacia a la pared, pasando cuidadosamente

los tornillos de montaje a través de los orificios en el escudete.

7) Atornille las bolas roscados en los tornillos de montaje.

Apriete las bolas roscados para fijar el artefacto al pared.

8) Inserte la bombilla recomendada.

9) Bajar el vidrio hacia abajo sobre el bombilla. Montar el inferior

del vidrio en la taza del artefacto.

INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL

AIRE LIBRE Y/O EN UN LUGAR MOJADO.

10) La superficie de montaje debe estar limpia, seca, ser plana y

1/4” más grande que el esdudete en todos los bordes.

Cualquier espacio libre entre la superficie de montaje y el

escudete que exceda de 3/16” debe corregirse según se

requiera.

11) Calafatee totalmente con compuesto de calafatear de

silicona alrededor donde el escudete sienta en la superficie

de la pared para impedir la entrada de agua en la caja de

conexiones.

Conectar el alambre de

suministro negro o rojo al

Conectar el alambre de

suministro blanco al

Negro

Blanco

*Cordon paralelo (redondo y liso) *Cordon paralelo (cuadrado y estriado)

Claro, marrón, amarillio o negro

sin hebra identificadora

Claro, marrón, amarillio o negro

con hebra identificadora

Alambre aislado (diferente del verde)

con conductor de cobre

Alambre aislado (diferente del

verde) con conductor de plata

*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).

Hilo Neutral

ARANDELA

CONCAVA

A

B

TIERRA DE LA

CAJA DE SALIDA

TORNILLO DE TIERRA,

VERDE

DEPRESIONES

TIERRA

ARTEFACTO

CONECTOR DE ALAMBRE

(NO SE PROVEE)

TIERRA DE LA

CAJA DE SALIDA

TORNILLO DE TIERRA,

VERDE

TIERRA

ARTEFACTO

GLASS

VIDRIO

BULB

BOMBILLA

CUP

TAZA

Advertising