Setup Horizontal System
Change Time/Div
Selects the horizontal
Time/DIV (scale factor) for the main or the window time base
The Horizontal Panel
Click on and rotate the blue knob to change
Time/Div.
If the waveform acquisition is stopped,
Time/Div control expands or compresses the
waveform.
Change Format
Click “
Time/Div” to set the Time base in Horizontal Setup window
Format: Set the waveform display format (Y-T, X-Y and Roll).
Y – T: Show the relative relation between vertical voltage and horizontal time
Roll: In Roll Mode, the waveform display updates from right to left
X – Y: Show CH1 value at X axis; CH2 value at Y axis