1.2.5 Electrical Specifications

Table 1-8. Rated Electrical Ranges

Specification

120 V Version

220 - 240 V Version

Rated voltage

120 VAC

220 - 240 VAC

Input voltage range

103.5

132 V

198

264 V

Rated frequency range

50

60 Hz

50

60 Hz

Input frequency range

49.5

60.5 Hz

49.5

60.5 Hz

Rated current

0.5 A

0.3 A

Power consumption

Approx. 15 W
(self-test with 10-cpi LQ characters)

Approx. 15 W

(self-test with 10-cpi LQ characters)

Insulation resistance

10 M

Ω,

minimum

(applying 500 VDC between AC
line and chassis)

10 M

, minimum

(applying 500 VDC between AC line

and chassis)

Dielectric strength

1000 VAC rms for 1 minute or
1200 VAC rms for 1 second
(between AC line and chassis)

1500 VAC rms for 1 minute

(between AC line and chassis)

1.2.6 Environmental Conditions

Table 1-9. Acceptable Environmental Conditions

Condition

Operating

Non Operating

Temperature

10

35

°

C (50

95

°

F)

*1

20

60

°

C (

4

122

°

F)

*2

Humidity

20

80% RH

*1, 3

5

85% RH

*2, 3

Shock resistance

1G (within 1 msec.)

2G (within 2 msec.)

*2

Vibration resistance

0.15 G

0.50 G

*2

*1 : For printer operation, conditions must be in the range shown in the figure below.

*2

: These conditions are applicable when the printer is in its shipping container.

*3

: Without condensation.

80%

55%

20%

Humidity
(% RH)

Guaranteed Range

(Degrees)

10

27

35

Figure 1-5. Temperature/Humidity of Range

Epson Stylus Color 200 /Epson Stylus 200

Product Description

Rev. A

1-7

Advertising