In the Table 2-1, if the control sequence is executed in incremental order, the carriage motor rotates
clockwise (CW). (The CR moves from 1st column to 80th column.)

Signals output from ports P105, P106, and P107 of the CPU determine the reference trip current level
used by the motor driver IC for drive current control. Table 2-2 lists the connection of the output
signals and the reference trip current levels.

Table 2-2. Connection between References and Output Signals

Reference
(Trip Current)

P105

P106

P107

Duty Change

601 mA

OFF

OFF

OFF

1, 2/3, 1/3, 0

481 mA

ON

OFF

OFF

As above

444 mA

OFF

ON

OFF

As above

403 mA

OFF

OFF

ON

As above

375 mA

ON

ON

OFF

As above

345 mA

ON

OFF

ON

As above

326 mA

OFF

ON

ON

As above

110 mA

OFF

ON

ON

Fixed to 1/3