Main Menu Display Functions & Messages

The meter displays various functions and messages during setup,
programming, and operation. The following table shows the main menu
functions and messages in the order they appear in the menu.

Display Parameter

Action/Setting

dp

Decimal point

Set decimal point

SCL

Scale

Enter the Scale menu

Npt

Number of Points

Set number of linearization points

in1

Scale Input 1

Input signal 1 value (mA)

D1

Scale Display 1

Scaled value for input 1

in2

Scale Input 2

Input signal 2 value (mA)

D2

Scale Display 2

Scaled value for input 2

CAL

Calibrate

Enter the Calibrate menu

Npt

Number of Points

Set number of linearization points

in1

Calibrate Input 1

Read input signal 1

D1

Calibrate Display 1

Enter value for input 1

in2

Calibrate Input 2

Read input signal 2

D2

Calibrate Display 2

Enter value for input 2

Setting the Decimal Point (dP)

Decimal point may be set with up to three decimal places or with no
decimal point at all.
Pressing the Right or Up arrow moves the decimal point one place to
the right until no decimal point is displayed, then it moves to the left
most position.

ENTER

dP

dd.dd

or

Select Decimal Point

Next