BUS Mode Installation

Introduction

The information in this section relates to WatchIN DT installation in BUS Mode only. Up to 32
BUS detectors can be installed on the ProSYS RS485 BUS, saving cabling time and enabling
remote control and diagnostics.

Terminal Wiring

+,-

Used for the connection of 12VDC power supply. Connect the (+) terminal to
the AUX RED and the (–) terminal to the COM BLK of the ProSYS terminals

YELLOW

Used for data communication with the ProSYS. Connect to the terminal to the
BUS YEL of the ProSYS

GREEN

Used for data communication with the ProSYS. Connect to the terminal to the
BUS GRN of the ProSYS

TAMPER

Used for the wiring for tamper detection, see below

LED
ENABLE

Used for the wiring for tamper detection, see below

Note:

All the terminals not mentioned in the table above are unused.

Cover and Back Tamper

COM

BLK

BUS

GRN

YEL

BUS

Mode:

Cover

+

Back tamper wiring

BACK

TAMPER (N.C)

ProSYS BUS

Short

AUX

RED

+

-

SET/

UNSET

AM

TAMPER

FREE

(YEL)

N.O. COM N.C.

FREE

(GRN)

LED

ENBL TEST

Cover Tamper Only

COM

BLK

BUS

GRN

YEL

BUS

Mode:

Cover

Tamper Wiring

Short

AUX

RED

+

-

SET/

UNSET

AM

TAMPER

FREE

(YEL)

N.O. COM N.C.

FREE

(GRN)

LED

ENBL TEST

ProSYS BUS

Cover Tamper to Zone Input

COM

BLK

BUS

GRN

YEL

AUX

RED

+

-

SET/

UNSET

AM

TAMPER

FREE

(YEL)

N.O. COM N.C.

FREE

(GRN)

LED

ENBL TEST

Zone

COM

Z1

Z2

Zone Input

Short

ProSYS BUS

BUS Mode:

Cover Tamper to Zone Input