WatchOUT PIR Installation Manual

15

E

n

g

li

s

h

WatchOUT ID: DIP Switches 1 - 5

ID

1

2

3

4

5

ID

1

2

3

4

5

01

OFF OFF OFF OFF OFF

17

OFF OFF OFF OFF ON

02

ON

OFF OFF OFF OFF

18

ON

OFF OFF OFF ON

03

OFF ON

OFF OFF OFF

19

OFF ON

OFF OFF ON

04

ON

ON

OFF OFF OFF

20

ON

ON

OFF OFF ON

05

OFF OFF ON

OFF OFF

21

OFF OFF ON

OFF ON

06

ON

OFF ON

OFF OFF

22

ON

OFF ON

OFF ON

07

OFF ON

ON

OFF OFF

23

OFF ON

ON

OFF ON

08

ON

ON

ON

OFF OFF

24

ON

ON

ON

OFF ON

09

OFF OFF OFF ON

OFF

25

OFF OFF OFF ON

ON

10

ON

OFF OFF ON

OFF

26

ON

OFF OFF ON

ON

11

OFF ON

OFF ON

OFF

27

OFF ON

OFF ON

ON

12

ON

ON

OFF ON

OFF

28

ON

ON

OFF ON

ON

13

OFF OFF ON

ON

OFF

29

OFF OFF ON

ON

ON

14

ON

OFF ON

ON

OFF

30

ON

OFF ON

ON

ON

15

OFF ON

ON

ON

OFF

31

OFF ON

ON

ON

ON

16

ON

ON

ON

ON

OFF

32

ON

ON

ON

ON

ON

ProSYS Programming

The following section describes the additional software programming options, added to the
ProSYS software, that concern the settings of the Without PIR as a BUS detector. Up to 32 BUS
detectors can be added to the system (16 in ProSYS 16) and each of them comes at the expense
of a zone in the system.
It is recommend reading and fully understanding the ProSYS Installation and User Manuals,
before programming the WatchOUT.

Notes:

The WatchOUT is compatible with the ProSYS software Version 4.xx and above.
The WatchOUT can be programmed via the U/D Software from UD Version 1.8 and above.
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring when
connecting the WatchOUT to the BUS

The WatchOUT is part of a new accessory category, BUS zones. Therefore, Adding/Deleting the
WatchOUT is identical to any other accessory with the following exception:

Each BUS Zone Detector should be assigned to a Regular Zone.

Any BUS detector can be assigned to a physical wired zone or to a virtual zone

.

Physical zone:

Any zone on the ProSYS PCB (zones 1-8) or on a wired zone expander

(ZE08, ZE16).

Virtual zone:

Any zone on a BUS zone expander defined as BZ08 or BZ16.

Notes:

Virtual BUS zones are cost effective. They enable to expand your system zones without adding physical zone
expanders.

The virtual BUS zone expander can be used only for BUS zone detectors.

To add a BUS zone expander select type BZ08 or BZ16 when adding a zone expander (Quick key [7][1][2])

To Add / Delete the WatchOUT 312PIR

1.

From the installer menu enter the Add/Delete menu: Quick Key

[7][1][9][5]

for BUS Zones

detectors

2.

Use the

/

or

/

keys to position the cursor over the Bus Zone

ID number for which you want to assign (or delete) a detector.

Note:

Make sure that the detector's physical ID number is identical to the ID number you select
during programming

3.

Place the cursor on the TYPE field and use the

/

key to select OPR12 for the

WatchOUT 312PIR detector.