Iii. furnace specifications, Dimensions & weights – Thermo Pride OMD-70 User Manual

Page 10

Advertising
background image

All installations and services must be performed by qualified service personnel.

III. FURNACE SPECIFICATIONS


MODEL

OMD-70

GMD-85


HEAT INPUT RATE (BTUH)

85,000

85,000

HEATING

CAPACITY

(BTUH)

71,000

69,700

BURNER NOZZLE (GPH X

ANGLE, HOLLOW CONE) 0.65X80A

-------

BURNER ORIFICE-NAT. GAS

---------

#17 DMS

BURNER ORIFICE-PROP. GAS ---------

#36 DMS

OIL PUMP PRESSURE (PSIG)

100 -------

GAS SUPPLY PRESSURE (IN.W.G.)
MINIMUM REQUIRED

PROPANE --------- 11
NATURAL --------- 4.5

MAXIMUM ALLOWED
PROPANE --------- 13.9
NATURAL --------- 13.9
GAS MANIFOLD PRESSURE (IN. W.G.)
PROPANE --------- 10 + 0.3
NATURAL --------- 3.5 + 0.3
VENT PIPE SIZE (INCHES) 4

4

DESIGN TEMPERATURE RISE (°F) 85

85

MINIMUM RETURN AIR TEMP. (°F) 55 55
SEASONAL EFFICIENCY
(AFUE*, %) 85

82


*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE
LOSSES.

ELECTRICAL RATINGS AND SETTINGS:
ELECTRICAL SUPPLY: 120 VAC / 60HZ / 1 PHASE
MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS
TOTAL RATED CURRENT (AMPS): 11.3 (OMD), 6.81 (GMD)
NOMINAL HEAT ANTICIPATOR SETTING -- 0.2 mA (OMD), 0.8 mA (GMD)

DIMENSIONS & WEIGHTS:
CABINET: WIDTH - 18 IN., DEPTH - 24 IN., HEIGHT - 57 IN.
NO.70 MOBILE HOME BASE: WIDTH - 18 5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.
WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN., HEIGHT - 14 ¼ IN.
COTTAGE BASE: WIDTH – 18 3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14¾ IN.
FILTER QUANTITY & SIZE: (2) @ 17 ¾ IN. x 13 ¾ IN. x 1 IN. EA.
APPROXIMATE SHIPPING WEIGHT: 240 LBS.

PRODUCT LISTED UNDER UL FILE NUMBER -- MP3241

9

Advertising