All installations and services must be performed by qualified service personnel.

38

After fuel valve opens,

does the burner ignite?

Check the fuel supply.

Open all manual shutoff

valves serving the unit.

Purge any air in the

fuel line.

No

No

Are the ignition electrodes

positioned correctly?

No

Reposition to

correct location.

Does the burner stay
lit past proof of flame

check?

Does the fan timer

energize the circulating

air blower after the 56

second time delay?

Check settings on fan

timer against those

on connection

diagram. Is blower

still inoperable

after time delay

with fan timer
set correctly?

Measure voltage

on the circulating

air blower terminals.

Is it 120 VAC?

Check wiring to

blower. If okay,

set fan selector

switch to manual.

If fan operates,

replace fan timer.

Yes

Yes

Yes

No

No

No

Does blower wheel

spin freely?

Is blower motor

capacitor functioning

properly?

Replace blower
motor capacitor.

Yes

Yes

Replace motor

Yes

No

Yes

Yes

Yes

Yes

No

Check for blower wheel

rubing against housing

or motor shaft spinning

freely. Adjust or replace

as necessary.

No

For the GMD, measure gas

supply pressure at inlet to

gas valve. Is it at least 4.5"

W.G. for natural gas or 11"

W.G. for L.P. gases? For

the OMD, is oil present in

the fuel line at the valve?

Check for blocked or severely

worn burner nozzle (OMD) or

burner orifice (GMD). Clean

or replace as required.

On the GMD, measure supply &

manifold pressures. Are they

constant over time and within the

allowable ranges? On the OMD,

is the oil tank full of fuel? Is the

fuel clean without contaminates?

Is the fuel filter dirty?

On the GMD, adjust supply

pressure to 4.5" W.G. for

natural & 11" W.G. for LP gases.

Adjust manifold pressure to 3.5"

W.G. for natural gas or 10" W.G.

for LP gases. If gas pressure

fluctuates, a pressure regulator

may be required or gas piping

may be too small for flow. On the

OMD, add or replace fuel and fuel

filter. Also, check flame sensor (GMD),

cad cell (OMD) for proper operation.

Advertising