Amprobe HD110C Digital-Multimeter User Manual

Page 13

Advertising
background image

7

OL Protection: 1500 V dc/1000 V ac rms

Transient Protection: 12 kV impulse (1.2 µS/50 µS)
based on EN 61010-1:2001 impulse requirement
for at CAT IV 1000 V product. This product should
not be used in installations where transients
exceed 12 kV.

DC Current

Ranges: 200 µA, 2 mA, 20 mA, 200 mA, 2 A

Resolution: 0.1 µA

Accuracy: 200 µA to 20 mA: ±(0.5 % rdg+2 dgts),
200 mA to 2 A: ±(1.0 % rdg+2 dgts)

Voltage Burden: 250 mV max.
(1 mV/1 µA on 200 µA Range),
(100 mV/1 mA on 2 mA Range),
(10 mV/1 mA on 20 mA Range),
(1.5 mV/1 mA on 200 mA Range),
(500 mV/1 A on 2 A Range)

OL Protection: A Input (F 2 A/1500 V,
size 8 x 65 mm IR fast blow ceramic)

AC Current (45 Hz to 1 kHz)

Ranges: 200 µA, 2 mA, 20 mA, 200 mA, 2 A

Resolution: 0.1 µA

Accuracy: 200 µA to 20 mA: ±(0.8 % rdg+4 dgts),
200 mA to 2 A: ±(1.2 % rdg+4 dgts)

Voltage Burden: 250 mV max. (1 V on 2 A range)

OL Protection: Same as DC Current.

Resistance

Ranges: 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ

Resolution: 0.1 Ω

Accuracy: 200 Ω ±(0.5 % rdg+4 dgts),
2 kΩ to 200 kΩ: ±(0.3 %rdg+2 dgts),
2 MΩ: ±(1.0 % rdg+4 dgts),
20 MΩ: ±(2.0 %rdg+4 dgts)

OL Protection: 1500 V dc/1000 V ac rms

Open Circuit Voltage, 200 Ω rng: 3.0 V dc typical;
all other rngs 0.3 V dc typical.

Diode/Continuity Test

Test Current: 1m A dc typical

Test/Open Circuit Voltage: 3.0 V dc Typical

Diode Accuracy: ±(1.5 % rdg +2 dgts)

Continuity Audible Threshold: < 50 Ω ± 25 Ω

Response Time: <100 msec

OL Protection: 1500 V dc/1000 V ac rms