MAINTENANCE AND REPAIR

If there appears to be a malfunction during the operation of the meter, the
following steps should be performed in order to isolate the cause of the
problem.

1. Check the battery. Replace the battery immediately when LCD displays

the Power is ≦2%.

2. Review the operating instructions for possible mistakes in operating

procedure.

Except for the replacement of the battery, repair of the meter should
be performed only by a Factory Authorized Service Center or by other
qualified instrument service personnel. The front panel and case can be
cleaned with a mild solution of detergent and water. Apply sparingly
with a soft cloth and allow to dry completely before using. Do not use
aromatic hydrocarbons, Gasoline or chlorinated solvents for cleaning.

Please remove all the batteries if users won’t use the Solar Module
Analyzer for a long time.

Battery Replacement / Recharging

When Rechargeable Batteries are used, please follow below steps to charge
the batteries

1. Connect the AC Adaptor with the Solar Module Analyzer.

2. Turn on the Solar Module Analyzer.

3. Press the BATTERY CHARGE button to start recharging.

4. During recharging (takes 10 hours), LCD displays “Power: Charge”.

5. After recharging, LCD displays “Power: 100%”.

6. Remove the AC Adaptor.

WARNING!

1. Do not use non-rechargeable batteries to perform charging.
2. Users are suggested to do recharging only when LCD displays the

Power is 2%.

3. Do not stop recharging when it is not finished so that the battery life

can be maintained.