Description of function keys, Func key, D-h /  key – Amprobe ACD-51HP Power-Quality-Clamp-Ons User Manual

Page 13: Max/min/pk key

Advertising
background image

ACD-51HP - ACD-56HPQ

4.2.

DESCRIPTION OF FUNCTION KEYS

4.2.1.

FUNC key

This key allows the user to cycle through each function’s measurement modes with each
key press.

V

: press FUNC key to select between voltage and frequency measurement.

A

: press FUNC key to select between current and frequency measurement.

: press

FUNC key to start phase sequence detection.

W

: press

FUNC key to select between active energy, reactive energy, apparent

energy, and power factor measurements on single-phase systems.

W3

Φ:

press

FUNC key to select between active energy, reactive energy, apparent

energy, and power factor measurements on three phase balanced systems.


On the ACD-56HPQ model only, press & hold the

FUNC key for at least 1 second to

activate the “Harmonic measurement mode”. With the rotary selector switch in the
following positions

V

: press and hold the

FUNC key for at least 1 second to activate the voltage

harmonic measurement. By pressing the H

↑ and H↓ keys the individual

harmonic values are displayed.

A

: press and hold the

FUNC key for at least 1 second to activate the current

harmonic measurement. By pressing the H

↑ and H↓ keys the individual

harmonic values are displayed.


This function mode is disabled by:
• Pressing and holding the FUNC key for at least 1 second.
• Rotating the selector to any other position.

More details about the

FUNC key use are specified in the measurements paragraphs.


4.2.2. D-H / key
This key enables the HOLD function. The symbol "

H

" is displayed when this function is

enabled. To disable this function:
• Press

the

D-H key again

• Rotate the rotary selector switch to another position.

Press and hold the

key for 1 second to illuminate the backlight. The backlight

automatically turns off about 5 seconds after the last rotary selector switch or button
actuation.

4.2.3. MAX/MIN/PK key
By pressing and holding the MAX/MIN/PK key for at least 1 second, the instrument
activates the maximum (MAX), minimum (MIN), average (AVG) and peak (PK)
measurement modes. All of these values are continually updated even if only one of them
is displayed. By repeatedly pressing the MAX/MIN/PK key each value is displayed with the
corresponding frequency. To disable this function:
• Press and hold the MAX/MIN/PK key for at least 1 second.