Technical specifications, Characteristics – Amprobe ACD-51HP Power-Quality-Clamp-Ons User Manual

Page 32

Advertising
background image

ACD-51HP - ACD-56HPQ

6. TECHNICAL SPECIFICATIONS

6.1. CHARACTERISTICS
Accuracy is indicated as [% of reading + digit number]. It is referred to the following
reference conditions: 23°C ± 5°C with RH <75%.


DC Voltage

Range Resolution Accuracy Input

impedance

1.6

÷ 599.9V

0.1V

±(1.0% rdg + 3 dgt)

1M

AC Voltage (TRMS)

Accuracy

Range Resolution

40

÷ 200Hz

200

÷ 400Hz

Input impedance

1.6

÷ 599.9V

0.1V

±(1.0% rdg+3 dgt) ±(5.0% rdg + 3 dgt)

1M

Max. Crest factor = 1.5

MAX / MIN / AVG / PEAK AC/DC Voltage

Function Range Resolution Accuracy

Response

time

MAX,MIN,AVG 10

÷ 599.9V

0.1V

±(5.0% rdg + 10 dgt)

500ms

PEAK

10

÷ 850V

1V

±(5.0% rdg + 10 dgt)

1ms

AC Current (TRMS)

Accuracy

Range Resolution

40

÷ 200Hz

200

÷ 400Hz

Overload protection

0.0

÷ 399.9A

0.1A

±(1.0% rdg+3 dgt) ±(5.0% rdg + 5 dgt)

600A RMS

Max. Crest factor = 2

MAX / MIN / AVG / PEAK AC Current

Function Range Resolution Accuracy

Response

time

Overload

protection

MAX,MIN,AVG 1.0

÷ 399.9A

0.1A

±(5.0% rdg + 10 dgt)

500ms 600A

RMS

PEAK

10

÷ 800A

1A

±(5.0% rdg + 10 dgt)

15ms 600A

RMS

Resistance and Continuity test

Range Resolution Accuracy Overload

protection

0.0

÷ 499.9Ω 0.1Ω

500

÷ 999Ω

1

1000

÷ 1999Ω

3

±(1.0% rdg + 5 dgt)

600V AC/DC RMS

Instrument emitted a buzzer for R<40

Frequency (with test leads)

Range Resolution Accuracy Overload

protection

40.0

÷ 399.9Hz

0.1Hz

±(0.5% rdg + 1 dgt)

600V RMS

Voltage range for frequency measure: 0.5

÷ 600V

Frequency (with jaws)

Range Resolution Accuracy Overload

protection

40.0

÷ 399.9Hz

0.1Hz

±(0.5% rdg + 1 dgt)

600A RMS

Voltage range for frequency measure: 0.5

÷ 400V

Active power, Reactive power, Apparent power

Range [kW], [kVAR], [kVA]

Resolution [kW], [kVAR], [kVA]

Accuracy

0.00

ч 99.99

0.01

100.0

ч 999.9

0.1

±(3.5% rdg + 3 dgt)

Accuracy defined for: sine wave, voltage 100

÷600V, current ≥1A, freq. 50-60Hz, Pf: 0.8i ÷ 0.8c

EN - 28

Advertising
This manual is related to the following products: