ProSoft Technology MVI71-DFNT User Manual

Page 152

Advertising
background image

Reference

MVI71-DFNT ♦ PLC 5

User Manual

EtherNet/IP Client/Server Communication Module

Page 152 of 175

ProSoft Technology, Inc.

February 3, 2011

The

M

ULTI

H

OP

option must be set to

Y

ES

.

The

M

ULTI

H

OP

tab portion of the dialog

box must be completed as shown in the following window:

Set the IP address value to the module’s Ethernet IP address. You must press

the "Insert" key to add the second line for ControlLogix Backplane and set the

slot number to zero.

Read commands transfer data to the PLC5 processor from the DFNT module. An

example rung used to execute a read command is shown in the following

diagram:

PLC5 Read Commands

In order to complete the configuration of the MSG instruction, select the

S

ETUP

S

CREEN

area of the MSG object. This displays the following dialog box.