Rosemount 5300 Series

LED ERROR MESSAGES

For Rosemount 5300 transmitters without display, a flashing Light Emitting
Diode (LED) is used for presentation of error messages.

Figure 7-25. Rosemount 5300
transmitters without display use
a LED for presentation of error
messages.

In normal operation, the LED flashes once every other second. When an error
occurs, the LED flashes a sequence that corresponds to the Code number
followed by a five second pause. This sequence is continuously repeated.

The following errors can be displayed:

Table 7-12. LED error codes.

Example

Modem error (code 6) is displayed as the following flash sequence:

3

Flashing LED

Code

Error

0

Ram Failure

1

FPROM

2

HREG

4

Microwave Module

5

Display

6

Modem

7

Analog Out

8

Internal Temperature

11

Hardware

12

Measurement

14

Configuration

15

Software

Seconds