Rosemount 5300 series, Reference manual – Emerson Process Management ROSEMOUNT 5300 User Manual

Page 186

Advertising
background image

Reference Manual

00809-0100-4530, Rev BA

July 2009

Rosemount 5300 Series

A-2

Display / Configuration (continued)

F

OUNDATION

Fieldbus

Class (Basic or Link
Master)

Link Master (LAS).

F

OUNDATION

Fieldbus

Block Execution Time

AI-block: 30 ms. PID-block: 40 ms.
ARTH-, ISEL-, OSPL-block: 65 ms. CHAR-block: 75 ms.

F

OUNDATION

Fieldbus

Instantiation

No.

Conforming F

OUNDATION

Fieldbus

ITK 5.0.

F

OUNDATION

Fieldbus

PlantWeb

®

Alert Support

Yes.

Damping

0-60 s (2 s, default value).

Electric

Power Supply

HART: 16-42.4 Vdc (16-30 Vdc in IS applications, 20-42.4 Vdc in Explosion-proof / Flameproof applications).
F

OUNDATION

Fieldbus: 9-32 Vdc (9-30 Vdc in IS applications, and 16-32 Vdc in Explosionproof / Flameproof

applications).
FISCO, IS applications: 9-17.5 Vdc.

Internal Power
Consumption

< 50 mW in normal operation.

Output

HART 4-20 mA current loop or F

OUNDATION

Fieldbus.

Quiescent Current Draw (
F

OUNDATION

Fieldbus)

21 mA

Signal on Alarm

Standard : Low = 3.75 mA, High = 21.75 mA.
Namur NE 43: Low = 3.60 mA, High = 22.50 mA.

Saturation Levels

Standard: Low = 3.9 mA, High = 20.8 mA.
Namur NE 43: Low = 3.8 mA, High = 20.5 mA.

IS Parameters

See Appendix B: Product Certifications.

Cable Entry

½ - 14 NPT for cable glands or conduit entries.
Optional: M20 x 1.5 conduit / cable adapter, M12 4-pin male eurofast

®

connector or A size Mini 4-pin male

minifast

®

connector.

Output Cabling

Twisted shielded pairs, 18-12 AWG.

Mechanical

Probes

Coaxial: 1.3 ft (0.4 m) to 19.7 ft (6 m).
Rigid Twin Lead: 1.3 ft (0.4 m) to 9.8 ft (3 m).
Flexible Twin Lead: 3.3 ft (1 m) to 164 ft (50 m).
Rigid Single Lead (0.3 in./8 mm): 1.3 ft (0.4 m) to 9.8 ft (3 m)
Rigid Single Lead (0.5 in./13 mm): 1.3 ft (0.4 m) to 14.8 ft (4.5 m)
Flexible Single Lead: 3.3 ft (1 m) to 164 ft (50 m).

Tensile Strength

4 mm Flexible Single Lead probe (model code 5A, 5B): 2698 lb (12 kN)
6 mm Flexible Single Lead probe (model code 6A, 6B): 6519 lb (29 kN)
Flexible Twin Lead probe: 2023 lb (9 kN).

Collapse Load

4 mm Flexible Single Lead probe (model code 5A, 5B): 3597 lb (16 kN)
6 mm Flexible Single Lead probe (model code 6A, 6B): 7868 lb (35 kN)

Sideway Capacity

Coaxial: 73.7 ft lbf or 3.7 lb at 19.7 ft (100 Nm or 1.67 kg at 6 m).
Rigid Twin Lead: 2.2 ft lbf or 0.22 lb at 9.8 ft (3 Nm or 0.1 kg at 3 m).
Rigid Single Lead: 4.4 ft lbf or 0.44 lb at 9.8 ft (6 Nm or 0.2 kg at 3 m).

Material Exposed to Tank
Atmosphere

• 316L SST (EN 1.4404), PTFE, PFA

(5)

and O-ring materials (Standard Probe, Material model code 1) or

• Alloy C-276 (UNS N10276), PTFE, PFA

(5)

and O-ring materials (Standard Probe, Material model code 2) or

• Alloy 400 (UNS N04400), PTFE, PFA

(5)

and O-ring materials (Standard Probe, Material model code 3)

• PTFE

(6)

(Standard Probe, Material model code 7) or

• PTFE

(6)

, 316 L SST (EN 1.4404) and O-ring materials (Standard Probe, Material model code 8)

• 316L SST (EN 1.4404), Ceramic (Al

2

O

3

), Graphite, Inconel (HTHP Probe, Material model code 1)

• Alloy C-276 (UNS N10276), Ceramic (Al

2

O

3

), Graphite, Inconel (HTHP Probe, Material model code 2 and H)

• 316L SST (EN 1.4404), Ceramic (Al

2

O

3

), Graphite, PFA, PTFE, Inconel (HP Probe, Material model code 1)

• Alloy C-276 (UNS N10276), Ceramic (Al

2

O

3

), Graphite, PFA, PTFE, Inconel (HP Probe, Material model code

2 and H)

• 316L SST (EN 1.4404), Ceramic (Al

2

O

3

), Graphite, PFA, PTFE, Inconel (C Probe, Material model code 1)

See “Ordering Information” on page A-21.

Advertising