Installation – Enviro WINDSOR 50-1578 User Manual

Page 15

Advertising
background image

15

Installation

O

UTSIDE

V

ERTICAL

I

NSTALLATIONS

:

To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “I

NSIDE

V

ERTICAL

I

NSTALLATIONS

- F

REESTANDING

” section and then finish it by performing the following (refer to Figure 14).

1. Install a tee with clean out on the outside of the house.
2. Install vent pipe upward from the tee. Make sure that you install support brackets to keep the vent

straight and secure.

3. Install ceiling thimble and secure the flashing as you go through the roof.
4. Ensure that the rain cap is approximately 900 mm (36”) above the roof.

Rain cap

Flashing

900mm

(36")

100mm

(4")

Tee with

cleanout

Fresh air

intake

75mm (3")

Clearance

Support

bracket

Type "L"

vent

Figure 14: Outside Vertical Installation.