Installation – Enviro WINDSOR 50-1578 User Manual

Page 17

Advertising
background image

17

Install blower

motor onto

exhaust blower

housings.

Completed assembly.

Exhaust Motor

Cover Plate

Access Panel

Installation

I

NSTALLATION

WITH

E

XTERIOR

M

OUNTED

E

XHAUST

B

LOWER

:

The WINDSOR can be equipped with an externally mounted exhaust blower (PART #50-492). This

optional kit will include all components necessary to install the exhaust blower on any external vertical

wall surface.
Choose a location for your stove that meets the requirements stated in this manual and allows installation

with the least amount of interference to house framing, plumbing, wiring, etc.

Included in the exterior mounted exhaust blower kit

are: 1 - Exhaust blower housing box.

1 - Blower cover plate.

1 - Hardware bag

1. Open the left side of the unit and disconnect the

exhaust blower wires from the harness. Remove the

exhaust blower by undoing the six (6) 6mm (1⁄4”)

hex head sheet metal screws that fasten the blower

to the housing.

2. Remove the back grill from the exterior exhaust

vent housing and remove the round cover plate

installed on the blower housing.

3. Install the round cover plate over the gasketed

opening in the stove where the exhaust motor was

removed from.

4. Install the exhaust blower motor in the Exterior Vent

Housing Box onto the exhaust blower housing.

Figure 18: Exterior Exhaust Blower.

5. Follow the procedures for I

NSTALLATION

- H

ORIZONTAL

E

XHAUST

T

HROUGH

W

ALL

I

NSTALLATION

. Place the unit in

the desired location. Cut the hole in the wall at the desired location. Install a wall thimble.

6. Drill holes in the wall thimble in the corresponding locations for wire and fresh air if needed. Install

wire clamps and feed wire through the hole in the thimble into the house. Tighten clamp on wire and

attach green ground wire (at the symbol) with the screw and star washer provided.

7. Attach a short or an adjustable section of 80mm (3”) of double wall pellet vent through the wall

thimble to the stove. Seal all

joints with silicone. Maintain

clearances to combustibles.

8. Apply silicone to the pipe in

the Exhaust Box, slide the pipe

into the exhaust vent. Mount

the Exhaust Box to the house.

Reinstall the back grill on the

Exterior Vent Housing Box.

Apply normal venting practices

when installing the vertical

vent pipe.

Figure 17: Removing Exhaust Blower.

Advertising