Installation – Enviro WINDSOR 50-1578 User Manual

Page 8

Advertising
background image

This unit may be installed in an alcove. Maintain the

clearances to combustibles shown in Figure 4.

Minimum Alcove width 1220mm (48 inches)

Minimum Alcove height 1220mm (48 inches)

Maximum Alcove depth 915mm (36 inches)

Install vent at clearances specified by

the vent manufacturer.

Minimum Width

1220mm (48")

Minimum Height

1220mm (48")

Maximum Depth

915mm (36")

Figure 4: Alcove Clearances.

Back wall

S

id

e

w

al

l

Adjacent

wall

100mm

(4")

100mm (4")

200mm

(7

7

/

8

inches)

150mm

(6")

Floor Protection

Figure 3: Minimum Clearances to Combustibles for

Freestanding Windsor.

These dimensions are minimum clearances but it

is recommended that you ensure sufficient room

for serving, routine cleaning and maintenance.
Side wall to unit 200mm (77⁄8 inches)

Back wall to unit 100mm (4 inches)

Corner to unit

100mm (4 inches)

In Front of unit 800mm (311⁄2” inches)

This pellet stove requires floor protection. The

floor protection must be non-combustible,

extending beneath the stove the full width and

depth of the unit including 150mm (6“) in front

for ember protection.
Hearth Pad Size:

Width: 650 mm

(25 5⁄8”)

Depth: 815mm

(32 1⁄8”)

Installation

C

LEARANCES

TO

C

OMBUSTIBLES

:

A

LCOVE

C

LEARANCES

:

8