Installation – Enviro WINDSOR 50-1578 User Manual

Page 16

Advertising
background image

Storm Collar

Existing Masonary Flue

Flexible Vent Connector (use

this 1.5m (5ft) section of pipe

to vent past the fireplace

damper or smoke shelf)

Seal Plate

Fireplace Damper

Location

Vertical Vent Pipe (single

wall stainless flex pipe or

solid PL vent)

Existing Fireplace

ENVIRO Windsor

Clean Out Tee

Rain cap - ensure cap is at

least 900mm (3 ft) above

the roof at the lowest point

1. Lock fireplace damper in the open

position.

2. Install a positive flue connector at the

fireplace dampers.

3. Connect a clean-out tee or a 90° elbow

to the exhaust pipe.

4. Install flexible stainless steel liner or listed

pellet vent to the top of the chimney.

Floor

Protection

Combustible Floor

Masonry Fireplace

Min 150mm

(6")

Mantel

Minimum 200mm (8")

from top of stove

Damper Removed

or Fastened Open

Clean-out

Fresh-air intake

should com from

chimney. If holes

already exist fresh-air

intake can be taken

through back of the

fireplace or through

the ash dump.

Installation

H

EARTH

M

OUNT

I

NSTALLATION

:

Figure 15: Hearth Mount - Side View.

Figure 16: Hearth Mount - Over View.

16