When installing the camera at a high place

,

use the ceiling plate to fix the

camera

.

Fix the ceiling plate tightly with four M4 screws

(

pan head

,

binding

head

,

etc

.).

When working with the camera upside down

,

support the camera to prevent

it from wobbling in order to attach or remove the rubber feet or the camera

-

to

-

mount safety wire

.

Keep the four rubber feet and four screws that have

been removed for reuse in case of a change in the installation

.

Ceiling mount

The camera is hung upside down from the ceiling or other location using the

ceiling plate

.

The procedure provided in the

"Installation Guide

/

Important Information"

[2

/

2]

explains this installation method

.

The weight of the camera

(

body only

)

is

Approx

.

4

.

4 kg

(

9

.

7 lb

.).

Reinforce the ceiling depending on its structure and

material to ensure the sufficient holding strength to support the total weight

including the camera and the mounting parts

,

and install

.

Standing mount

The camera is fixed to a high place using the ceiling plate

.

Follow the same procedure as for the ceiling mount

,

except for the direction

of the camera and logo plate inversion

.

Tripod mount

Attach the tripod by fixing two screws to the two screw holes for tripod

.

Use 1

/

4

-

20UNC screws and tighten them securely

,

and set the tripod on a

flat surface with no steps

.

Also refer to the instructions in the

"Installation Guide

/

Important Information"

[2

/

2]

,

if necessary

.

4.5 – 5.5 mm (0.18 – 0.22 in.)

1/4-20UNC

Desktop

Install the camera on a stable

,

horizontal surface such as a table

.

Also refer to the instructions in the

"Installation Guide

/

Important Information"

[2

/

2]

,

if necessary

.

Connecting the Camera

1

3

4

2

5

7

6

8

9 10

11

12

13

14

16 15

1. LAN terminal

This terminal is for a network connection

(

RJ

-

45 connector

).

The built

-

in PoE

++

(

Power over Ethernet

++)

function allows the camera to be

powered by a PoE

++

HUB that complies with IEEE802

.

3bt Type 3 or higher

via a LAN cable

.

Use a category 5e or higher STP

(

shielded type

)

LAN cable

,

up to 100 m

(

328 ft

.)

in length

.

Important

Some PoE

++

HUBs can limit the power for each port

,

but applying limits

may interfere with performance

.

In this case

,

do not limit the power

.

Some PoE

++

HUBs have limits for the total power consumption for

the ports

,

which can interfere with performance when multiple ports

are in use

.

For more information

,

check the instruction guide for the

corresponding PoE

++

HUB

.

2. SD card slot

For future expansion

.

3. RESET switch

Initialize the camera settings to the factory defaults

.

Refer to the "Settings

Guide" for details

.

4. 12G-SDI OUT terminal

Terminal for 12G

-

SDI output

(

BNC

).

5. SERVICE switch

Set the camera number and frame frequency operated by the IR remote

controller

.

(

Refer to "Before using the camera" > "SERVICE switch settings"

.)

6. TIME CODE terminal

Terminal for time code input

/

output

(

BNC

).

7. Memory card slot

For

future expansion

.

8. 3G-SDI OUT terminal

Terminal for 3G

-

SDI output

(

BNC

).

9. GEN-LOCK/SYNC terminal

Terminal for the synchronization signal input

/

output

(

BNC

)

to synchronize the

videos from the camera and external devices

.

If the reference signal is unstable

,

external synchronization is not possible

.

Subcarriers do not synchronize

.

10. INPUT1/INPUT2 terminal

XLR terminals for audio input

.

It can be used for microphone

/

line input

.

Microphone power

(

Phantom power

)

: 48 V DC

11. LED for phantom power supply

It is lit in blue when the phantom power is supplied

.

12. MIC terminal

Stereo

3

.

5 mm

(

0

.

14 in

.)

terminal for audio input

.

It can be used for

microphone

/

line input

.

Microphone power: 2

.

4 V DC

13. RS-422 terminal

Serial terminal

(

RJ

-

45 connector

)

for RS

-

422

.

Connect the GNDs on both ends to stabilize the voltage level of the signal

.

Use category 5e or higher STP cables

.

Pin number

Function

1

TX

-

Output

(-)

2

TX

+

Output

(+)

3

RX

-

Input

(-)

4

GND

5

GND

6

RX

+

Input

(+)

7

NC

8

NC

14. HDMI OUT terminal

Terminal for HDMI output

.

15. DC IN 12V terminal

Pow

er supply terminal for the external DC power supply

.

Connect to the power supply that meets the installation site requirements

(

approved products and the environment

)

and product specifications

.

In addition

,

note that inrush current may cause the power supply to be

insufficient and cause failure when power is turned on

.

Therefore

,

it is

recommended to use a power supply with a power capacity of two to three

times the rated capacity or more

.

Input: 10

.

8 V

20 V DC

,

3

.

5 A

(

acceptable maximum load current

).

4

-

pin XLR connector

.

Pin number

Function

4

3

2

1

1

GND

2

NC

3

NC

4

10

.

8

20 V DC

16. GND terminal

Ground terminal of the camera

.

It is used to install a lightning arrester

(

surge protection devices

).

Note

The camera is not equipped with a power switch

.

To turn the camera on

and off

,

insert and remove the cable of the external DC power supply

connected to the "15

.

DC IN 12V terminal" or the PoE

++

HUB connected

to the "1

.

LAN terminal"

,

which supplies power

.

When both the PoE

++

HUB and the external DC power supply are

connected

,

the external DC power supply takes priority

.

If the external

DC power supply is disconnected while both are connected

,

power to

the camera will be interrupted

.

In this case

,

power can be restored by

disconnecting and reconnecting the LAN cable

.

The audio input terminals

(

"10

.

INPUT1

/

INPUT2 terminal"

,

"12

.

MIC

terminal"

)

and microphones should be set using the Settings Page

.

Refer

to the "Settings Guide" for details

.

Specifications

Please refer to the

'

Specifications

'

in the

'

Appendix

'

of the "Settings Guide"

for specifications not listed below

.

Pan operation range: Horizontal

±

170

°

Tilt operation range: Vertical

-

30

°

+

90

°

Operating Environment: Temperature: 0

+

40

(+

32

°

F

+

104

°

F

)

Humidity: 10%

90%

(

without condensation

)

Storage Environment: Temperature: 0

+

40

(+

32

°

F

+

104

°

F

)

Humidity: 10%

90%

(

without condensation

)

Power Consumption: PoE

++

Input: Approx

.

37

.

4 W

*

max

.

(

body only

)

DC Input: Approx

.

36

.

7 W max

.

(

body only

)

*

Class 5

(

40

.

0 W required

)

for power supply devices

Dimensions

(

W x H x D

)

: Approx

.

200 x 269 x 208 mm

(

7

.

87 x 10

.

59 x 8

.

19 in

.)

(

excluding protrusions

)

Weight: Approx

.

4

.

4 kg

(

9

.

7 lb

.)

(

body only

)

Country Regulations

About wireless communication

Regarding countries and regions where radio communication functions are

acceptable

Since the utilization of the radio communication functions can be legally

restricted by a country or region

,

it may not be possible to utilize out of the

country or the region where the product is purchased

.

Canon shall not be

liable for any incidents that may incur as a result of the utilization of the

radio communication functions in any country or region other than where the

product is purchased

.

FCC NOTICE

Remote Camera

,

Model Name: CR

-

N700

This device complies with Part 15 of the FCC Rules

.

Operation is subject

to the following two conditions:

(

1

)

This device may not cause harmful

interference

,

and

(

2

)

this device must accept any interference received

,

including interference that may cause undesired operation

.

Note: This equipment has been tested and found to comply with the limits for

a Class A digital device

,

pursuant to Part 15 of the FCC Rules

.

These limits are designed to provide reasonable protection against harmful

interference when the equipment is operated in a commercial environment

.

This equipment generates

,

uses

,

and can radiate radio frequency energy

and

,

if not installed and used in accordance with the user manual

,

may cause

harmful interference to radio communications

.

Operation of this equipment

in a residential area is likely to cause harmful interference in which case the

user will be required to correct the interference at his own expense

.

Do not make any changes or modifications to the equipment unless

otherwise specified in the manual

.

If such changes or modifications should

be made

,

you could be required to stop operation of the equipment

.

Use of shielded cable is required to comply with class A limits in Subpart B

of Part 15 of FCC Rules

.

Model: CR

-

N700

(

including WLAN Module Model ES202

,

FCC ID: AZD239

/

IC: 498J

-

239

)

This device complies with Part 15 of FCC Rules and ISED

'

s applicable

licenceexempt RSS standard

(

s

).

Operation is subject to the following two

conditions:

(

1

)

this device may not cause interference

,

and

(

2

)

this device must accept anyinterference

,

including interference that may

cause undesired operation of this device

.

This equipment complies with FCC

/

ISED radiation exposure limits set

forth for an uncontrolled environment and meets the FCC radio frequency

(

RF

)

Exposure Guidelines and RSS

-

102 of the ISED radio frequency

(

RF

)

Exposure rules

.

This equipment should be installed and operated keeping

the radiator at least 20 cm or more away from person

'

s body

.

This transmitter must not be co

-

located or operated in conjunction with any

other antenna or transmitter

.

FDA regulation

This product has not been evaluated by the Food and Drug Administration

(

FDA

)

for use as a medical device

.

When incorporated into a system with

medical applications

,

FDA regulations may apply

.

Therefore

,

please consult

your legal advisor to determine whether FDA regulations apply

.

Complies with

IMDA Standards

DB00671

European Union regulatory notices:

Remote Camera

,

Model Name: CR

-

N700

Warning

This is a class A product

.

In a domestic environment this product may cause

radio interference in which case the user may be required to take adequate

measures

.

Use of shielded network cable is required to comply with Class A limits in

EN55032

.

Wireless LAN Specifications

Frequency range: 2

,

401 MHz

2

,

473 MHz

Maximum output power: 9

.

48 dBm

For EU

Hereby

,

Canon Inc

.,

declares that the radio equipment type CR

-

N700 is in

compliance with Directive 2014

/

53

/

EU

.

The full text of the EU declaration of

conformity is available at the following internet address:

http:

//

www

.

canon

-

europe

.

com

/

ce

-

documentation

For UK

Hereby

,

Canon Inc

.,

declares that the radio equipment type CR

-

N700 is

in compliance with the relevant statutory requirements

.

The full text of the

declaration of conformity is available at the following internet address:

https:

//

www

.

canon

-

europe

.

com

/

ce

-

documentation

/

Only for European Union and EEA

(

Norway

,

Iceland and Liechtenstein

)

and

United Kingdom

These symbols indicate that this product is not to be disposed of with your

household waste

,

according to the WEEE Directive

(

2012

/

19

/

EU

),

the Battery Directive

(

2006

/

66

/

EC

)

and

/

or

national legislation implementing those Directives and

the UK Waste Electrical and Electronic Equipment

Regulations and the UK Batteries and Accumulators

Regulations

.

If a chemical symbol is printed beneath the symbol shown above

,

in accordance with the Battery Directive and the UK Batteries and

Accumulators Regulations

,

this indicates that a heavy metal

(

Hg = Mercury

,

Cd = Cadmium

,

Pb = Lead

)

is present in this battery or accumulator at

a concentration above an applicable threshold specified in the Battery

Directive and the UK Batteries and Accumulators Regulations

.

This product should be handed over to a designated collection point

,

e

.

g

.,

on an authorized one

-

for

-

one basis when you buy a new similar product or

to an authorized collection site for recycling waste electrical and electronic

equipment

(

EEE

)

and batteries and accumulators

.

Improper handling of

this type of waste could have a possible impact on the environment and

human health due to potentially hazardous substances that are generally

associated with EEE

.

Your cooperation in the correct disposal of this product

will contribute to the effective usage of natural resources

.

For more information about the recycling of this product

,

please contact your

local city office

,

waste authority

,

approved scheme or your household waste

disposal service or visit www

.

canon

-

europe

.

com

/

sustainability

/

approach

/.

CANON INC

.

30

-

2

,

Shimomaruko 3

-

chome

,

Ohta

-

ku

,

Tokyo 146

-

8501

,

Japan

Canon U

.

S

.

A

.

Inc

.

One Canon Park

,

Melville

,

NY 11747

,

U

.

S

.

A

.

Tel No

.

1

-

800

-

OK

-

CANON

(

1

-

800

-

652

-

2666

)

CANON EUROPA N

.

V

.

Bovenkerkerweg 59

,

1185 XB Amstelveen

,

The Netherlands

Advertising